59Use instructions
7.1.35 SMS Enable/-3dB Alarm
In this screen you can enable sending -3dB alarm through SMS, that is no longer active
to overcome the 2/3 of the power set. Set here the name of the station in “String ID”.
7.1.36 GSM Field/String Id
It can be displayed in this screen, the field strength of the GSM signal and set an alarm
in the absence of electricity for a time period set.
7.1.37 Phone N.1 .... Phone N.8
With the transmitter can “talk” more SIM cards.
The number is defined with the customer.
In these masks are set phone numbers in international format and permissions.
The number can be enabled globally for transmission and reception of SMS (en.), to
send commands (cmd.), to request and receive state machine (sts.), to receive the echo
of commands sent by any other numbers (glb.), to get SMS text or digital (PC.).
7.1.38 SMS Diagnostic
Here you can see the number of SMS sent and received successfully.
For more detail see “SMS List” section.