76 Maintenance
8.3 Malfunction (effects, causes and solutions)
Effect Cause Solution
Transmitter does not turn on Power cord defective or
missing
Auxiliary power incor-
rect (MAINS LED on front
panel off)
Fault in power stage
Replace the cable or con-
nect to apparatus
Call the manufacturer
Call the manufacturer
Transmitter does not reach
the required power
Transmitter in Stand By
No interlock connection
(if TC/TS option)
PLL not locked (ON AIR
LED on front panel off)
Power supply fault
RF module fault
Measure point fault
Set the transmitter in RF
ON
Connect interlock connec-
tion
Call the manufacturer
Call the manufacturer
Call the manufacturer
Call the manufacturer
Transmitter transmits on a
frequency different from
required frequence
PLL board fault
VCO board fault
Call the manufacturer
Call the manufacturer
No modulation in output and
on display
Absence or interruption
audio cables
MPX board fault
Stereo Coder board fault
Modulation off
Connect or change audio
cables
Call the manufacturer
Call the manufacturer
Activate modulation by
related menù
No modulation in output, but
displayed
MPX board fault
Stereo Coder board fault
Call the manufacturer
Call the manufacturer
Modulation in output that not
reaches the desired value
Low audio level input
MPX board fault
Increase source audio
level
Increase ETG input sen-
sitivity or call the manu-
facturer
No stereo modulation Stereo carrier off
Absence or interruption
audio cables
Stereo Coder board fault
Absence Stereo Coder
board
Turn on the stereo carrier
from the related menu
Connect or change audio
cables
Call the manufacturer
Transmitter can not be
used for stereo broa-
dcasts
One or more fans stopped Fans fault
Fans power supply fault
Call the manufacturer
Call the manufacturer