5. Setting of Registers
5.1 Register Input
Press F for 2 sec The digits in Actual value display flash.
98 is displayed when Registers are protected by security code.
To unlock Registers :-
Press > Select Target window
Enter 250565 The security code
Thereafter, the required Register is displayed. To alter value of Register proceed as follows:-
Press > The Actual value display reads 01 for Register 1
Use keypad 0 to 9 To enter desired Register number
Press > The value of that Register is displayed in Target Window
Press C To clear old value
Use keypad 0 to 9 To enter desired Register value
Press > The Register value is stored in memory. The Actual Value display indicates
next Register number
A number of Registers may be set sequentially.
Press F for 2 sec The Register entry is ended. Actual position is again displayed
Registers without function cannot be accessed.
Once Registers have been unlocked, you may alternate between operation and Register entry
mode without the need for further security code entry.
The Registers can be locked away, by either
Powering down, or
Selecting Register 98; press > ; press F for 2 sec.