MAX/MIN TEMPERATURE ALARM
Relative Temperature
Value to Setpoint (Att=1)
Absolute Temperature
Value (Att=0)
Temp.Set + LAL *
Temp.Set + HAL **
Temp.Set + LAL + AFd or
Set - ILALI + AFd (LAL < 0)
Temp.Set + HAL - AFd (HAL > 0)
Temp.LAL (LAL with sign)
Temp.HAL (HAL with sign)
Temp.LAL + AFd
Temp.HAL - AFd
Minimum temperature
alarm
Maximum temperature
alarm
Returning from
minimum temp. alarm
Returning from
maximum temp. alarm
* if LAL is negative, Set + LAL < Set
** if HAL is negative, Set + HAL < Set
Setpoint - LAL
AFd
Off
Setpoint + HAL
AFd
Setpoint - LAL + AFd
Setpoint + HAL - AFd
Setpoint
LAL
AFd
HAL
AFd
LAL + AFd
HAL - AFd