Output Characteristics
Digital output:
MODEL DEFAULT EN60730 (max 250 Vac) UL60730 (max 120 Vac) UL60730 (max 240 Vac)
EZ-HT Compressor 12(8) A 16 FLA - 96 LRA 12 FLA - 72 LRA
EZ-MT /
EZ-LT
Compressor 12(8) A 16 FLA - 96 LRA 12 FLA / 72 LRA
Defrost NO 8(4) A - NC 6(3) A
NO 8 A - NC 6 A resistive
1/8 HP
NO 8 A - NC 6 A resistive
1/2 HP
Fan 5(2) A
3 A resistive
1.4 FLA / 7.5 LRA
3 A resistive
1.4 FLA / 7.5 LRA
Mechanical Characteristics
Housing: PC+ABS UL94 V-0 resin casing, polycarbonate window, thermoplastic resin keys
Dimensions: Front: 76.4x35 mm (3.01x1.38 in.); depth: 59 mm (2.32 in.) (without terminals)
Terminals: Screw terminals for wires with cross-section of 2.5 mm
2
(13 AWG)
Connectors: TTL for connection to Copy Card (maximum lenght = 3 m (9.84 ft))
Humidity: Use / Storage: 10 ... 90 % RH (non-condensing)
Regulations
Food Safety: The device complies with standard EN13485 as follows:
suitable for storage
application: air
climate range A
measurement class 1 in the range -25 ... 15 °C (-13 ... 59 °F) (*)
(* exclusively using Eliwell probes)
NOTE: The technical specifications stated in this document regarding measurement (range, accuracy, resolution, etc.) refer strictly to the
instrument and not to any accessories provided, such as the probes.