USING THE COPY CARD
The Copy Card is connected to the serial port (TTL) and allows rapid programming of the instrument parameters. Access Installer parameters by
entering ‘PA2’, scroll through the folders using and until folder FPr appears. Select it using , scroll through the parameters using
and , then select the function using (eg. UL).
Upload (UL):
Select UL and press . This function uploads the programming parameters from the instrument to the card. If the
procedure is a success,y, will appear on the display, otherwise ‘n’ will appear.
Format (Fr): This command is used to format the copy card (recommended when using the card for the first time).
Important: the Fr parameter deletes all data present. This operation cannot be cancelled.
Download: Connect the Copy Card when the instrument is switched off. At power-on, data is downloaded from the copy card to the
instrument automatically. At the end of the lamp test, the display will show ‘dLy’ if the operation was successful and ‘dLn
if not.
UPLOAD
DOWNLOAD
OR
NOTE: After downloading, the instrument works with the settings of the new map just downloaded.