7. Twist the lter clockwise until it is disengaged.
Remove the lter and keep upright; remove towel.
8. Drain the lter before disposing in a trash can.
9. Remove protective cap from the new lter.
10. Mark the current date on the lter label.
11. Attach the lter to the lter head with label facing
outward by rmly inserting into the head and by
rotating the lter head counterclockwise, if required.
Note: Filter label should be readable from the front of
the lter during installation.
12. Restore power back to the unit.
13. Turn on water supply.
14. Verify proper dispensing by placing cup or any
object in front of sensor area and verify water
dispenses. Dispense at least two gallons of water to
bleed o any trapped air from supply lines and ne
carbon particles from the lter.
15. Check all the lines and connections for water leaks.
Repair connections if necessary.
Note: Once power is applied to the bottle ller, the
GREEN LED light should illuminate showing
good lter status along with the LCD Bottle
Counter.
GREEN: 0 - 80% of Filter Life or 0 - 11
Months (Whichever Comes First).
YELLOW: 80 - 100% of Filter Life or 11 - 12
Months (Whichever Comes First).
RED: 100% Plus of Filter Life or 12
Months (Whichever Comes First).
16. Attach the top cover on the cooler unit.
17. Install the 4 phillips screws using a phillips
screwdriver.
Filter