Operating modes (temporary settings)
2280073 Rev.1 Page 26
Operating modes (temporary settings)
7.1 Setting of operating modes
Several operating modes can be temporarily set. This temporary setting is possible without
entering any password and applies for one charging cycle only. Installed batteries as well as
batteries removed from the vehicle can be charged using the functions described in 7.2 to 7.4.
The procedure is subsequently described in tabular form.
7.2 Charging mode for lithium-ion batteries, temporary
The MC1500 is in its permanently set operating mode "charging Pb" and is to be set to
"Charging LIO" for one charging cycle.
Message on display
Press button 1 "On/OFF" to switch on unit
Pb no contact
Press button 4/5 „up or downuntil
Charging LIO
Press button 3 „Enter“
LIO no contact
Connect battery, red L / black L
Battery will be recognized
CHRG 12V on
Battery charging starts
charging 12V
Battery charging active
12V LIO charge
Yellow LED on if charging current >3A
Green LED on if charging current <3A
Press button 2 "Start/Stop"
LIO 12V standby
Disconnect battery
System test
Pb no contact
7.3 Charging mode for lead-acid batteries, temporary
The MC1500 is in its permanently set operating mode "Charging LIO" and is to be set to
"Charging Pb" for one charging cycle.
Message on display
Press button 1 "On/OFF" to switch on unit
LIO no contact
Press button 4/5 "Up or Down" until
Charging Pb
Press button 3 "Enter"
Pb no contact
Connect battery, red L / black L
Battery is recognized
CHRG 12V on
Battery charging starts
charging 12V
Battery charging active
12V Pb charge
Yellow LED on if charging current >3A
Green LED on if charging current <3A
Press button 2 "Start/Stop"
Pb 12V standby
Disconnect battery
System test
LIO no contact