5 Troubleshooting
Issue Possible cause and remedy
No LED indicators
are illuminated
Check that the power supply is connected
correctly.
Check that the power supply is a 12V or 24V
supply.
The red error LED
indicator is flashing
There may be a problem with the VHF antenna sys-
tem. This can be confirmed using proAIS2. If the
'High VSWR' alarm is active please check for the fol-
lowing:
Faulty VHF antenna/cable/connectors
Poor connection at the VHF antenna/cable/
connectors
Suitability of the VHF antenna (for AIS only we
recommend antennas covering 162MHz / for
splitter variants we recommend antennas
covering to 159MHz)
VHF antenna location (ensure that is isn't
mounted near other transmitting antennas or
sources of interference, metal structures, or
other obstructions)
The red 'error' LED
indicator is
illuminated
Check that the unit is configured with a valid
MMSI number. This can be confirmed using the
Configuration tab in proAIS2
Check that the GPS antenna has a stable
position fix. This can be confirmed using the GPS
Status tab in proAIS2
Check that the power supply is within 12 - 24V.
This can be confirmed using the Diagnostics tab
of proAIS2