1
INSTALLATION
* Install filtration system including pump,filter tank and multiport valve.
* The filter system should be installed as close as possibie to the swimming pool and preferably at a level
of 0.50 metres below the surface of the water in the swimming pool. Make sure there is drainage available
at the place where the filter is to be installed.
* PUMP
1.Only qualified,licensed personnel should install pump and wiring.
2.Electrical Contractors Please Note:All 110 volt 60Hz pump must be wired to the main power supply
trough an approved and correctly rated contractor.
3.Allow for gate valve in suction piping.
4.Pump suction and discharge connections have moulded in
beyond these stops.
thread stops,do not try to screw pipe in
* FILTER TANK and MULTIPORT VALVE
1.Loading the sand media.Filter sand media is loaded through the top opening of the filter.
a.Loosen the plastic clamps from tank neck.
b.Cap internal pipe with plastic cap to prevent sand from entering it.
c.We recommend filling tank approximately 1/2 way with water to provide a cushion effect when the filter
sand is poured in. This helps protect the under-drain laterals from excessive shock.
d.Carefully pour in correct amount and grade of filter sand.Be sure center pipe remains centered in opening.
Sand surface should be leveled and should come to about the middle of the filter tank.Remove plastic cap
from internal pipe.
2.Assemble filter control valve to filter tank.
a.Insert filter control valve(with O'ring in place)into the tank neck,taking care that the center pipe slips
into the hole in the bottom of the valve.
b.Place two plastic clamps around valve flange and tank neck and tighten just enough so that the valve may
Be rotated on tank for final positioning.
c.Carefully screw pressure gauge(with O'ring in place)into tapped hole in valve body.Do not over-tighten.
d.Connect pump to control valve opening marked PUMP with hose.After connections are made,tighten
clamps with screwdrive,tapping around clamp with screwdrive handle to help seat valve flange clamp.
3.Make return to pool pipe connection to control valve opening marked RETURN and complete other
necessary plumbing connections,suction lines to pump,waste,etc.
4.To prevent water leakage,be sure all pipe connections are tight.
FILTER & PUMP COMBO
Installation & Operating
Instruction
EMFS14122972
4
By-passes filter for circulating water to pool
Used after backwash to flush dirt from valve
Cleaning Filter by reversing the flow
By-passes filter, used for vacuuming to waste or lowering water level
CLOSED Shuts off all flow to filter or pool
RECIRCULATE
WASTE
RINSE
BACKWASH
FILTER
Valve Position
Normal Filtration and Vacuuming
Function
THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING
SYSTEM (e.g., CLAMP, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE
SYSTEM AND BECOME PRESSURIZED . PRESSURIZED AIR CAN CAUSE THE LID OR VALVE TO
BE BLOWN OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE
TURN PUMP OFF BEFORE CHANGING VALVE POSITION.
WARNING
!
!
TO PREVENT DAMAGE TO THE PUMP AND FOR PROPER OPERATION OF THE SYSTEM,
CLEAN PUMP STRAINER AND SKIMMER BASKETS REGULARLY.
!
DO NOT UNSCREW SCREWS OF FLANGE CLAMP WHILE PUMP IS RUNNING.
!
EM-VALVE FOR "ULTRA" REPLACEMENT PARTS
FSU-4TP FSU-4P FSU-6TP FSU-6P FSU-8TP FSU-8P
1
2
3
4
5
6
7
8
9
10
11
12
1
3
Key No.
Part No.
Product Description
Qty
1
01013130
Handle for 1.5"4-way Valve
1
2
03018160
Pin for handle
1
3
01013131
Fixation for 1.5"4-way Valve Handle
1
4
03011003
4*12 Self-drilling screw
3
5
01013132
Pressing Ring
1
6
01181060
Washer for 1.5"4-way Valve Handle
1
7
02011095
O-Ring for Rotor
2
8
02311010
Spider Gasket
1
9
06021014
Plastic pressure gauge With O-Ring (28Psi)
1
10
01013134
1.5"4-way Valve Body
1
11
89280104
Sight Glass with O-Ring
1
12
01013137
1.5"4-way Valve Rotor Connector
1
01013133
Rotor for 1.5"4-way Valve
1
01013135
Diffuserfor 1.5"4-way Valve
1
13
02011184
O-Ring for Diffuser
1
Question and Answer IconNeed help?

Do you have a question about the emaux FSU-4TP and is the answer not in the manual?

emaux FSU-4TP Specifications

General IconGeneral
Brandemaux
ModelFSU-4TP
CategoryWater Pump
LanguageEnglish

Summary

EM-VALVE FOR "ULTRA" REPLACEMENT PARTS

Valve Position Functions

Describes the function of each valve position (FILTER, BACKWASH, RINSE, WASTE, RECIRCULATE, CLOSED).

FILTER & PUMP COMBO Installation & Operating Instruction

INSTALLATION Overview

General steps for installing the filtration system, pump, and multiport valve.

PUMP Installation and Wiring

Details regarding pump installation and electrical connections.

FILTER TANK and MULTIPORT VALVE Installation Steps

Instructions for loading sand, assembling the filter control valve, and connecting the pump.

Critical Safety Warnings

Safety precautions regarding high pressure, air, and valve operation.

INSTALL/START-UP OF FILTRATION

Priming the Pump

Instructions for priming the pump and filter system for operation.

Filter Operation and Maintenance

Guidance on filter operation, backwashing, and pressure monitoring.

AMU PUMP REPLACEMENT PARTS

AMU Pump Component List

A list of replacement parts for the AMU pump series.

PRIMING PUMP Safety Guidelines

Important safety warnings and electrical requirements for pump priming.

Related product manuals