28. TROUBLESHOOTING
PROBLEM CAUSE HOW MANAGE
Pump does not turn on
There is not power supply.
Protection fuse is broken
Main board failure
Connect pump to main supply
Replace fuse, see Fuse replacement
procedure.
Replace cirucit, see Main board replacement
procedure.
Pump is not dosing but
solenoid is operating
Foot filter is obstructed
Unprimed pump (suction hose
is empty)
Air bubbles in the hydraulic
circuit
Product to dose is generating
gas
Clean foot filter
Prime the pump, see How to prime pump
head
Check valves, hoses and fittings and let air flow
away
Turn on venting valve and let air flow away. Use
a self-venting pump head model.
Pump is not dosing and
solenoid isn’t operating or
slightly operating.
Crystals block the balls inside
the valves
Injection valve obstructed
Clean valves and try to dose 2-3 liters of normal
water
Change valves
Display shows ERROR
MEM
Error in data storage
Restore default value, see LOAD DEFAULT
procedure.
Display shows ERROR
DATA
Error in data setting
Check the value set. If correct and the error still
persist, the pump could be undersized
Display shows WRONG
PASSWORD
Error in password enter
Restore a new password, see RESET PASSWORD
procedure
Display shows INPUT OPEN
In mA and VOLT working mode only:
no signal input
Check INPUT signal