Note
Weather proofing is required! The remote mount antenna kit
includes coaxial sealant for the cable connections for the lightning
arrestor, antenna, and Gateway. The coaxial sealant must be applied
to guarantee performance of the wireless field network. See Figure
4-3 for details on applying weather proofing.
Figure 4-3: Applying Coaxial Sealant to Cable Connections
Table 4-1: Remote Antenna Kit Options
Kit
option
Antenna Cable 1 Cable 2 Lightning
arrestor
WL2 1/2 Wavelength
Dipole Omni-
Directional +6 dB
Gain
50 ft. (15,2
m) LMR–
400
N/A Head mount, jack
to plug Gas
discharge tube 0.5
dB insertion loss
WL3 1/2 Wavelength
Dipole Omni-
Directional +6 dB
Gain
30 ft. (9,1
m) LMR–
400
20 ft. (6,1
m) LMR–
400
In-line, jack to jack
Gas discharge tube
0.5 dB insertion
loss
WL4 1/2 Wavelength
Dipole Omni-
Directional +6 dB
Gain
40 ft. (12,2
m) LMR–
400
10 ft. (3,0
m) LMR–
400
In-line, jack to jack
Gas discharge tube
0.5 dB insertion
loss
WN2 1/2 Wavelength
Dipole Omni-
Directional +8 dB
Gain
25 ft. (7,6
m) LMR–
400
N/A Head mount, jack
to plug Gas
discharge tube 0.5
dB insertion loss
September 2020 Quick Start Guide