Page #1 background image
Liebert
®
APM
User Manual APM 90 Integrated Modular UPS

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Emerson Liebert APM 90 and is the answer not in the manual?

Emerson Liebert APM 90 Specifications

General IconGeneral
BrandEmerson
ModelLiebert APM 90
CategoryUPS
LanguageEnglish

Summary

Special Declaration

Personnel Safety

Safety guidelines for personnel involved with the UPS.

Product Safety

Safety guidelines for product operation and environment.

Safety Precautions

High Leakage Current Warning

Warning about high leakage current and earth connection requirements.

Backfeed Protection Warning

Protection against back-feeding voltage into the static bypass input.

Hazardous Battery Voltage Warning

Warning about hazardous battery voltage levels.

Chapter 1 Overview

1.2.3 System Control Principle

Control principles for normal, abnormal mains, and module failures.

1.3 Operation Modes

Different operating modes of the UPS.

1.4 Battery Management

Battery management functions, including charging and testing.

1.5 Battery Protection

Battery protection mechanisms like low pre-warning and EOD.

Chapter 2 Mechanical Installation

2.1 Precautions

General precautions for mechanical installation.

Warning: Professional Installation Required

Requirement for professional installation.

Note: 3-Phase, 5-Wire Input Supply Required

Requirement for a 3-phase, 5-wire input supply.

Warning: Battery Hazards

Safety warnings related to battery handling.

2.2 Preliminary Check

Steps for preliminary checks before installation.

2.3 Environmental Requirement

Environmental specifications for UPS installation.

2.3.1 UPS Location Selection

Guidelines for selecting the UPS location.

2.3.2 Battery Location Selection

Guidelines for selecting the battery location.

2.4 Mechanical Requirement

Mechanical requirements for UPS components.

2.4.2 Moving The Cabinet

Procedures and warnings for moving the UPS cabinet.

2.4.6 Installing Power Module And Output Distribution Module

Procedures for installing power and output distribution modules.

Chapter 3 Electrical Installation

3.1 Wiring Of Power Cable

Wiring requirements for UPS power cables.

3.1.1 System Configuration

Requirements for UPS input, bypass, output, and battery cables.

3.1.2 Maximum Steady State AC And DC Currents

Table of maximum currents for UPS selection.

3.1.6 Protective Earth

Procedures and warnings for protective earth connection.

3.1.7 External Protective Device

Recommendations for installing external circuit breakers and RCDs.

3.1.8 Power Cable Connection Procedures

Step-by-step procedures for connecting power cables.

Warning: Hazardous Battery Terminal Voltage 400Vdc

Warning about hazardous battery terminal voltage.

Chapter 4 Operator Control And Display Panel

Chapter 5 Operating Instructions

5.2 UPS Start-Up Procedures

Step-by-step procedures for starting the UPS.

5.2.1 Start-Up Procedures (Into Normal Mode)

Steps to start the UPS in normal mode.

5.2.2 Start-Up Procedures (Into Battery Mode, Battery Cold Start)

Steps to start the UPS in battery mode from a cold start.

5.7 UPS Shutdown Procedures

Step-by-step procedures for shutting down the UPS.

5.7.1 Completely Powering Down The UPS

Steps to completely power down the UPS and load.

Chapter 6 Battery

6.2 Safety

Critical safety precautions for working with batteries.

Warning: Hazardous Battery Voltage Present Behind Covers

Warning about hazardous battery voltage levels.

6.6 Battery Protection

Battery protection features including BCB.

6.7 Battery Installation And Connection

Procedures for battery installation and connection.

6.7.2 Battery Connection

Procedures and warnings for connecting batteries.

Chapter 7 Dual Bus System

7.1 Installation Of Dual Bus System

Installation procedures for dual bus systems.

Chapter 9 Communication

Chapter 10 Service And Maintenance

10.1 Safety

Safety precautions for UPS service and maintenance.

10.4.1 Service Procedures of Power Module

Procedures for servicing power modules.

10.4.2 Service Procedures of Bypass Module

Procedures for servicing bypass modules.

10.4.3 Service Procedures of Output Distribution Module

Procedures for servicing output distribution modules.

Chapter 11 Specifications

11.4 Electrical Characteristics (Input Rectifier)

Electrical specifications for the input rectifier.

11.5 Electrical Characteristics (Battery)

Electrical characteristics related to the battery.

11.6 Electrical Characteristics (Inverter Output)

Electrical characteristics of the inverter output.

11.7 Electrical Characteristics (Bypass Mains Input)

Electrical characteristics of the bypass mains input.