Manual Supplement
00809-0100-4851, Rev AA
2017
Rosemount™ 3051S Series of Instrumentation
High Pressure Solutions
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 23
Operation and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 23
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 24
Safety Instrumented Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 25
Advanced HART Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 25
Specifications and Reference Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 26
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 52

Other manuals for Emerson Rosemount 3051S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Rosemount 3051S and is the answer not in the manual?

Emerson Rosemount 3051S Specifications

General IconGeneral
TypePressure Transmitter
Stability±0.125% of URL for 5 years
Ambient Temperature Range-40 to 85°C (-40 to 185°F)
Pressure TypeAbsolute, Gauge, Differential
Accuracy±0.025% of span
Output4-20 mA with HART
Communication ProtocolsHART, FOUNDATION Fieldbus
Material316L SST
Housing MaterialAluminum
Explosion ProtectionFM, CSA, ATEX, IECEx
Process Connection1/2–14 NPT
Electrical Connection1/2" NPT
Environmental RatingIP66, NEMA 4X
Power Supply10.5 to 42 VDC
Response TimeTypically 100 ms