Product Data Sheet
00813-0100-4530, Rev DA
December 2010
Rosemount 5300 Series
30
TABLE 8. Measuring Range and Minimum Dielectric Constant
TABLE 10. Maximum recommended Viscosity and Coating / Build-up
Rigid Single Lead Flexible Single Lead
(1)
Coaxial Rigid Twin Lead Flexible Twin Lead
Maximum Measuring Range
9 ft. 10 in. (3 m)
for 8 mm probes.
14 ft. 9 in. (4.5 m)
for 13 mm probes
164 ft (50 m) 19 ft 8 in. (6 m) 9 ft 10 in. (3 m) 164 ft (50 m)
Minimum Dielectric Constant
1.4 (Std)
(1.25 if installed in a
metallic bypass or
stilling well)
(1)
(2)
1.6 (HP/HTHP/C)
(1.4 if installed in a
metallic bypass or
stilling well)
(1)
(2)
(1) Probe end projection software function will improve the minimum measurable dielectric constant. Consult the factory for details.
(2) May be lower depending on installation.
1.4 (Std), up to 49 ft (15 m)
(1)
1.6 (HP/HTHP/C), up to 49 ft (15 m)
(1)
(Std/HP/HTHP/C)
1.8, up to 82 ft (25 m)
(1)
2.0, up to 115 ft (35 m)
(1)
3, up to 138 ft (42 m)
4, up to 151 ft (46 m)
6, up to 164 ft (50 m)
1.2 (Std)
1.4 (HP/C)
2.0 (HTHP)
1.4 (Std)
(Std)
1.4, up to 82 ft (25 m)
(1)
2.0, up to 115 ft (35 m)
(1)
2.5, up to 131 ft (40 m)
(1)
3.5, up to 148 ft (45 m)
6, up to 164 ft (50 m)
TABLE 9. Remote Housing Measuring Range
Dielectric
Constant
Rigid Single
8 mm
Rigid Single
13 mm
Flexible Single Coaxial Rigid Twin Flexible Twin
1 m
Remote
Housing
Chamber / pipe
installations 4 in.
(100 mm)
1.4
2
80
1.4
2
80
4 ft (1.25 m)
10 ft (3 m)
(1)
10 ft (3 m)
4 ft (1.25 m)
4 ft (1.25 m)
10 ft (3 m)
(1)
15 ft (4.5 m)
(1)
15 ft (4.5 m)
(1)
15 ft (4.5 m)
(1)
4 ft (1.25 m)
4 ft (1.25 m)
10 ft (3 m)
(1)
33 ft (10 m)
(1)
(2)
33 ft (10 m)
(1)
(2)
33 ft (10 m)
(1)
(2)
4 ft (1.25 m)
4 ft (1.25 m)
159 ft (48.5 m)
(1)
19 ft
(6 m)
10 ft (3 m)
(1)
10 ft (3 m)
(1)
10 ft (3 m)
(1)
4 ft (1.25 m)
4 ft (1.25 m)
10 ft (3 m)
(1)
33 ft (10 m)
(1)
(2)
33 ft (10 m)
(1)
(2)
33 ft (10 m)
(1)
(2)
4 ft (1.25 m)
98 ft (30 m)
(1)
159 ft (48.5 m)
(1)
Tank installations
2 m
Remote
Housing
Chamber / pipe
installations 4 in.
(100 mm)
1.4
2
80
1.4
2
80
9 ft (2.75 m)
10 ft (3 m)
(1)
10 ft (3 m)
9 ft (2.75 m)
9 ft (2.75 m)
10 ft (3 m)
(1)
15 ft (4.5 m)
(1)
15 ft (4.5 m)
(1)
15 ft (4.5 m)
9 ft (2.75 m)
9 ft (2.75 m)
10 ft (3 m)
(1)
33 ft (10 m)
(1)
(2)
33 ft (10 m)
(1)
(2)
33 ft (10 m)
(1)
(2)
9 ft (2.75 m)
9 ft (2.75 m)
154 ft (47 m)
(1)
19 ft
(6 m)
10 ft (3 m)
(1)
10 ft (3 m)
(1)
10 ft (3 m)
(1)
9 ft (2.75 m)
9 ft (2.75 m)
10 ft (3 m)
(1)
33 ft (10 m)
(1)
(2)
33 ft (10 m)
(1)
(2)
33 ft (10 m)
(1)
(2)
9 ft (2.75 m)
98 ft (30 m)
(1)
154 ft (47 m)
(1)
Tank installations
3 m
Remote
Housing
Chamber / pipe
installations 4 in.
(100 mm)
1.4
2
80
1.4
2
80
10 ft (3 m)
15 ft (4.5 m)
15 ft (4.5 m)
15 ft (4.5 m)
14 ft (4.25 m)
14 ft (4.25 m)
15 ft (4.5 m)
(1)
33 ft (10 m)
(1)
(2)
33 ft (10 m)
(1)
(2)
33 ft (10 m)
(1)
(2)
14 ft (4.25 m)
14 ft (4.25 m)
149 ft (45.5 m)
(1)
19 ft
(6 m)
10 ft (3 m)
(1)
33 ft (10 m)
(1)
(2)
33 ft (10 m)
(1)
(2)
33 ft (10 m)
(1)
(2)
14 ft (4.25 m)
98 ft (30 m)
(1)
149 ft (45.5 m)
(1)
Tank installations
(1) Accuracy may be affected up to + 1.2 in. (30 mm).
(2) Required chamber/pipe size is 3 or 4 in. (75 -100 mm).
Coaxial Twin Lead Single Lead
Maximum Viscosity
500 cP 1500 cP 8000 cP
(1)
(2)
(1) Consult your local Emerson Process Management representative
in the case of agitation/turbulence and high viscous products.
(2) Be cautious in HTHP viscous or crystallizing media applications
where temperature at instrument connection is significantly lower
than process temperature with risk of coating in the upper part of
probe that may reduce the measurement signal. Consider using
HP or STD probes in such applications.
Coating / Build-up
Coating not
recommended
Thin coating
allowed, but no
bridging
Coating allowed