Product Data Sheet
00813-0100-4530, Rev DA
December 2010
37
Rosemount 5300 Series
Canadian Standards Association (CSA) Approval
This product meets the Dual Seal Requirements of
ANSI/ISA 12.27.01-2003.
Cert. no. 1514653
E6
(1)
Explosion-proof with internal Intrinsically Safe Circuits [Exia]
Class I, Div. 1, Groups B, C and D;
Temp Code T4.
Class II, Div. 1 and 2, Groups E, F and G;
Class III, Div. 1
Ambient temperature limits -50 °C to +70 °C
(3)
Approval valid for HART, FOUNDATION fieldbus, and Modbus
options.
I6, IF
(1)
Intrinsically Safe Exia:
Class I, Div. 1, Groups A, B, C, and D.
Temp Code T4.
4-20 mA / HART model: U
i
=30 Vdc, I
i
=130 mA, P
i
=1.0 W,
C
i
=7.26 nF, L
i
=0 H.
F
OUNDATION fieldbus model: U
i
=30 Vdc, I
i
=300 mA,
P
i
=1.3 W, C
i
=0 nF, L
i
=0 H.
FISCO model: U
i
=17.5 Vdc, I
i
=380 mA, P
i
=5.32 W, L
i
=C
i
=0.
Approval valid for HART, F
OUNDATION fieldbus, and FISCO
options.
Installation Drawing: 9240 030-937
Ambient temperature limits -50 °C to +70 °C
(3)
IECEx Approval
IECEx NEM 06.0001X
SPECIAL CONDITIONS FOR SAFE USE (X)
The intrinsically safe circuits do not withstand the 500 Vac test as
specified in IEC 60079-11 clause 6.4.12.
Impact and friction hazards need to be considered according to
EN 60079-0 clause 8.1.2 when the transmitter and part of
antennas exposed to the exterior atmosphere of the tank is made
with light metal alloys and of category II 1G EPL Ga.
The Ex ia version of model 5300 FISCO field device may be
supplied by an [Ex ib] FISCO power supply when the power supply
is certified with three separate safety current limiting devices and
voltage limitation which meets the requirements for type Ex ia.
E7
(1)
Flameproof:
Ex ia/db ia IIC T4 Ga/Gb (-40 °C T
a
+70 °C
(3)
)
Ex ta IIIC T79°C
(2)
(-40 °C T
a
+70 °C
(3)
)
U
m = 250 V.
Approval valid for HART, F
OUNDATION fieldbus, and Modbus
options.
I7
(1)
, IG
(1)
Intrinsically Safe:
Ex ia IIC T4 (-50 °CT
a
+70 °C
(3)
).
Ex ia/ib IIC T4 Ga/Gb (-50 °CT
a
+70 °C
(3)
).
Ex ta IIIC T79°C
(2)
(-50 °CT
a
+70 °C
(3)
).
4-20 mA / HART model: U
i
=30 Vdc, I
i
=130 mA, P
i
=1.0 W,
C
i
=7.26 nF, L
i
=0 H.
F
OUNDATION fieldbus model: U
i
=30 Vdc, I
i
=300 mA,
P
i
=1.5 W, C
i
=0 nF, L
i
=0 H.
FISCO model: U
i
=17.5 Vdc, I
i
=380 mA, P
i
=5.32 W, C
i
=0 nF,
L
i
<1 μH.
Installation Drawing: 9240 030-938
Approval valid for HART, F
OUNDATION fieldbus, and FISCO
options.
(1) Ordering Information Code for Product Certificates, see page 8 and page 13.
(2) +69 °C with F
OUNDATION fieldbus or FISCO option.
(3) +60 °C with F
OUNDATION fieldbus or FISCO option.