EasyManua.ls Logo

Emerson Rosemount 5301 - Page 5

Emerson Rosemount 5301
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Data Sheet
00813-0100-4530, Rev DA
December 2010
5
Rosemount 5300 Series
P High Pressure
(3)
:
Max 392 °F (200 °C): 3500 psi @ 392 °F and 5000 psi @ 100 °F (243 bar @ 200 °C
and 345 bar @ 38 °C)
3B, 4A, 5A, and 5B
Expanded
C
Cryogenic Temperature
(3)
(4)
-321 °F (-196 °C)
Max 392 °F (200 °C): 3500 psi @ 392 °F and 5000 psi @ 100 °F (243 bar
@ 200 °C and 345 bar @ 38 °C)
3A, 3B, 4A, 5A, 5B (Only
SST)
Material of Construction
(5)
: Process Connection /
Probe
Probe Type Valid Operation
Temperature and Pressure
Standard Standard
1 316L SST (EN 1.4404) All S, H, P, C
Expanded
2 Alloy C-276 (UNS N10276). With plate
design if flanged version. Up to class 600,
PN 63 for HTHP/HP probes.
3A, 3B, 4A S, H, P
3 Alloy 400 (UNS N04400). With plate
design if flanged version.
3A, 3B, 4A, 5A, 5B S
7 PTFE covered probe and flange. With
plate design.
4A and 5A S
8 PTFE covered probe 4A and 5A S
H Alloy C-276 (UNS N10276) process
connection, flange, and probe
(6)
3A, 3B, 4A H, P
Sealing, O-ring Material (Consult the factory for other o-ring materials)
Standard Standard
N None
(7)
VViton
®
fluoroelastomer
E Ethylene Propylene
KKalrez
®
6375 perfluoroelastomer
B Buna-N
Probe Type Process Connection Probe Lengths
Standard Standard
3B Coaxial, perforated. For level and interface
measurement, or easier cleaning.
Flange / 1 in.
(12)
, 1.5 in., 2 in.
(12)
Thread Min: 1 ft 4 in. (0.4 m). Max:
19 ft 8 in. (6 m)
4A Rigid Single Lead (8 mm) Flange / 1 in.
(12)
, 1.5 in., 2 in.
(12)
Thread
/ Tri-Clamp
Min: 1 ft 4 in. (0.4 m). Max: 9
ft 10 in. (3 m)
4B Rigid Single Lead (13 mm)
(8)
Flange / 1 in., 1.5 in., 2
in.
Thread /
Tri-Clamp
Min: 1 ft 4 in. (0.4 m). Max:
14 ft 9 in.
(4.5 m)
5A Flexible Single Lead with weight
(9)
Flange / 1 in.
(12)
, 1.5 in., 2 in.
(12)
Thread
/ Tri-Clamp
Min: 3 ft 4 in. (1 m). Max: 164
ft (50 m)
5B Flexible Single Lead with chuck
(10)
Flange / 1 in.
(12)
, 1.5 in., 2 in.
(12)
Thread
/ Tri-Clamp
Min: 3 ft 4 in. (1 m). Max: 164
ft (50 m)
Expanded
1A Rigid Twin Lead
(12)
Flange / 1.5 in., 2 in.
(12)
Thread Min: 1 ft 4 in. (0.4 m). Max: 9
ft 10 in. (3 m)
2A Flexible Twin Lead with weight
(12)
Flange / 1.5 in., 2 in.
(12)
Thread Min: 3 ft 4 in. (1 m). Max: 164
ft (50 m)
3A Coaxial (for level measurement)
(11)
Flange / 1 in.
(12)
, 1.5 in., 2 in.
(12)
Thread Min: 1 ft 4 in. (0.4 m). Max:
19 ft 8 in. (6 m)
4U Dynamic Vapor Compensation
Single Rigid Probe for 2 in. pipes
(13)
Flange / 1.5 in. Thread
Min: 2 ft 5 in. (0.76 m). Max:
13 ft (4 m)
TABLE 1. 5301 and 5302 Level and/or Interface in Liquids Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.