Quick Installation Guide
00825-0100-4004, Rev DB
December 2011
Rosemount 8800D
23
Care must be taken when installing the equipment with process fluid in the range of -202 °C
to +427 °C, as the ambient temperature for the electronics and electronics housing must
stay in the temperature range of -50 °C to +70 °C.
The remote mounted sensor may only be connected to the transmitter with the associated
cable, supplied by the manufacturer.
Special conditions for safe use (x)
For information regarding the dimensions of the flameproof joints, the manufacturer shall be
contacted.
The Flowmeter shall be provided with special fasteners of property class A2-70 or A4-70.
Care must be taken when installing the equipment with process fluid in the range of -202 °C
to +427 °C, as the ambient temperature for the electronics and electronics housing must
stay in the temperature range of -50 °C to +70 °C.
The remote mounted sensor shall only be connected to the transmitter with the associated
cable, supplied by the manufacturer.
Chinese Certifications (NEPSI)
Flameproof Certification
E3 Certification No. GYJ071327X
Ex d [ia] IIC T6 (-50 °C to 70 °C)
Intrinsic Safety
I3 Certification No. GYJ071171X
Ex ia IIC T4/T5
T4: (-60 °C to 70 °C)
T5: (-60 °C to 40 °C)
Input Parameters:
U
i
= 30 Vdc
I
i
= 185 mA
P
i
= 1.0 W
C
i
= 0 F
L
i
= 0.97 mH
Type N Certification
N3 Certification No. GYJ071193X
Ex nAnL IIC T5 (-40 °C to70 °C)
42 Vdc Max
K3 E3, I3, and N3 Combination
4004_RevDB.fm Page 23 Wednesday, November 23, 2011 3:06 PM