Installation, Operation and Maintenance Manual
VA-DC-000-1952 Rev. 0
 
April 2021
10
Section 2: Installation
Installation
2.7  Hydraulic Fluid
The ECAT actuators are shipped with the reservoir lled to operation level. Before commissioning 
and periodically afterwards, check to ensure the uid level is correct. The reservoir is equipped 
with a sight gauge. Should hydraulic uid need to be added or replaced, use only factory approved 
hydraulic uid.
This specication covers hydraulic uids which are approved by engineering for use in the ECAT 
system at a temperature range from -50 °F to 140 °F (-46 °C to 60 °C).
2.7.1  Approved Fluids
Standard Fluid [use with -20 °F to 140 °F (-29 °C to 60 °C) applications]
ConocoPhillips Megaow™ AW HVI Hydraulic Oil 22
Shell Tellus S2 V 22
Mobil DTE 10 Excel™ 22
Low Temperature Fluid [use with -50 °F to 140 °F (-46 °C to 60 °C) applications]
Mobil Univis™ HVI 13
Although other brands of uid matching the same specications may be used, to maintain the 
warranty and ensure trouble free operation, always check with the factory before substituting any 
other uid.
2.8  Accumulator
2.8.1  Introduction
The ECAT Actuator is equipped with a hydraulic accumulator. As the accumulator utilizes the 
pressurized pipeline gas, the ECAT will be in an unpressurized state when shipped from the factory.
When using this procedure, refer to the ECAT Actuator General Arrangement drawing and Hydraulic 
Schematic for the unit being worked on. Schematics shown in this document are for illustration 
purposes only.
!
WARNING
This unit contains high-pressure hydraulic uid and high pressure pipeline gas. Exercise caution when 
performing any type of maintenance. Wear proper safety attire and required personal protective 
equipment, including safety glasses.