EasyManua.ls Logo

Emerson Shafer ECAT - Recommended Annual Inspection

Emerson Shafer ECAT
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation, Operation and Maintenance Manual
VA-DC-000-1952 Rev. 0
April 2021
20
Section 6: Maintenance
Maintenance
6.4 Recommended Annual Inspection
It is recommended the following components and features of the ECAT to be evaluated at least
once a year.
Check hydraulic uid levels
Check the pressure gauges
Check bolts and ttings for tightness
Check for external oil leaks
Check the pneumatic ttings with a leak detection product such as Snoop liquid leak
detector from Swagelok or comparable.
Check handpump operation functions properly
If/When possible, perform a function test (See Section 4.6 for instructions on how to
perform a function test)
Check accumulator and thermal volume controller function
Check the breather on the hydraulic reservoir
Check the return lter, if included
Qualied service personnel are available upon request. Please feel free to contact:
EMERSON AUTOMATION SOLUTIONS
ACTUATION TECHNOLOGIES
Address: 2500 PARK AVENUE WEST
ONTARIO, OH 44906
Telephone: (419) 529-4311
Fax: (419) 529-3688