EasyManua.ls Logo

Emerson Site Supervisor - User Manual

Emerson Site Supervisor
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
026-1800 Rev 3 02-AUG-2016
Site Supervisor Controller User Guide 2.0

Table of Contents

Other manuals for Emerson Site Supervisor

Questions and Answers:

Emerson Site Supervisor Specifications

General IconGeneral
BrandEmerson
ModelSite Supervisor
CategoryController
LanguageEnglish

Summary

Hardware Overview

Technical Specifications

Details technical specifications of the Site Supervisor including operating temperature, humidity, and power.

Housing Dimensions and Mounting

Provides dimensions and mounting options for the Site Supervisor unit, including DIN Rail compatibility.

Wiring Diagrams

Illustrates wiring diagrams for the Site Supervisor 2.0, showing terminal connections and ports.

Site Supervisor Power, Serial, and IO Positions

Details the locations of power, serial, and I/O ports on the Site Supervisor unit.

RS485 I;O Network Boards and Peripherals

The I;O Network

Explains the RS485 I/O Network connection for data interchange between input and output boards.

MultiFlex Boards

Overview of the MultiFlex line of control system boards offering input, output, and smart control solutions.

MultiFlex RTU Support

Details support for MultiFlex RTU (Rooftop Unit Board) for HVAC unit control.

MultiFlex RCB Support

Explains MultiFlex RCB (Rooftop Control Board) support for HVAC zone control applications.

Site Supervisor Display

Describes the Site Supervisor display as a remote UI for performing critical actions on the controller.

Site Supervisor Display

Technical Specifications

Lists the technical specifications for the Site Supervisor display unit.

Site Supervisor Display Screens

Details the user interface screens, including login, categories, and application selection.

Software Overview

Suction Groups

Explains suction group applications for cycling compressors to maintain constant suction pressure.

Lighting Control

Explains the application for controlling indoor and outdoor lights based on various inputs.

HVAC Control

Describes the HVAC control application for managing HVAC equipment, rooftop units, and air handlers.

Demand Control

Details monitoring power demand and managing loads in response to high demand situations.

Utility Monitoring

Tracks consumption of metered services like electricity, gas, and water.

HVAC Zone

Explains HVAC Zone applications for managing multiple HVAC units to maintain temperature and humidity.

Alarm Configuration

Alarm Configuration

Guides on setting up alarm parameters, descriptions, types, and categories.

Alarm Communications Setting

Details configuring alarm communication settings for SMTP (emailing) and texting alarms.

Temperature Differential Alarms

Describes temperature differential alarms and their properties for AHU and T-Stat devices.

Appendix B: Troubleshooting

Related product manuals