Do you have a question about the Emerson SP1203 and is the answer not in the manual?
Model | SP1203 |
---|---|
Type | Servo Drive |
Input Voltage | 200-240V AC |
Output Current | 3A |
Control Method | PWM |
Control Mode | Position, Speed, Torque |
Communication Protocol | RS-485 |
Communication Interface | RS-485 |
Protection Features | Overcurrent, Overvoltage, Undervoltage, Overtemperature |
Provides essential information for avoiding safety hazards and product damage.
Highlights severe electrical shock and lethal risks when working with or near the drive.
Emphasizes professional installation, system design, and personnel training for safe operation.
Explains Regen operation as a regenerative front end for four-quadrant operation with bi-directional power flow.
Provides tables detailing Unidrive SP drive current and power ratings at various voltages and switching frequencies.
Shows power and control connections for a single Regen and single motoring drive system.
Illustrates AC and DC power connections for Unidrive SP size 1 Regen drive and motoring drive.
Details power and control connections for multiple motoring regen solution with an external SPMC.
Details ground connections for Unidrive SP sizes 1 to 6, SPMA, and SPMD, including cable standards.
Illustrates power and control connections for multiple motoring regen with an external charging resistor.
Depicts power connections for multiple Regen and multiple motoring drives utilizing Unidrive SPMC.
General safety precautions for mechanical and electrical installation, emphasizing competence.
Considers access, environmental protection, and cooling requirements for proper installation.
Ensures installation is safe under normal and fault conditions, referring to Chapter 6 for details.
Notes that drive enclosures are not fire enclosures and require a separate fire enclosure.
Highlights the importance of correct installation and wiring layout to prevent electromagnetic interference.
Provides dimensions and specifications for Regen inductors, including fixing types and losses.
Warns about severe electric shock hazards from AC supply, DC connections, and internal drive parts.
Mandates using an approved isolation device to disconnect AC supply before removing covers or servicing.
Alerts to potentially lethal voltage in capacitors after AC supply disconnection, requiring a 10-minute wait.
Addresses safety isolation for equipment connected via plug and socket, recommending automatic isolation means.
Outlines general EMC guidelines, including ground connections and clearances for sensitive equipment.
Details requirements for operating in first and second environments, emphasizing EMC filter and shielded cable use.
Recommends using specified filters and shielded motor cables, observing layout rules for compliance.
Details grounding arrangements in accordance with EMC guidelines, including cable connections and clearances.
Shows required connections for SPMC to terminals T.84 and T.85, including status relay utilization.
Lists control terminal functions, I/O configurations, and programming details for Unidrive SP.
Describes the sequence of events during Regen drive enablement, including line synchronization and controller activation.
Provides steps for commissioning the Regen drive and motoring drives, including parameter setup and enable sequence.
Explains how drive trips are indicated on the display and LED status, including trip codes.