EasyManua.ls Logo

Emerson Unidrive M400 - Page 128

Emerson Unidrive M400
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
128 SI-Ethernet User Guide
Issue: 1
Example
To write the value 12345 to drive parameters 0.20.021 through 0.20.023 and read the
values of parameters 0.20.024 through 0.20.026 (Transaction ID=42) using standard
addressing:
Master request data Slave response data
Byte
Hex
value
Description Byte
Hex
value
Description
0-1 00 2A
Transaction ID
(42)
0-1 00 2A
Transaction ID
(42)
2-3 00 00
Protocol ID
(0=TCP/IP)
2-3 00 00
Protocol ID
(0=TCP/IP)
4-5 00 17
Length
(Bytes=6)
4-5 00 0F
Length
(Bytes=15)
6FF
Unit identifier
(FF= Drive)
6FF
Unit identifier
(FF= Drive)
717
Function code
(23)
717
Function code
(23)
8-9 47 E7
Start read register
(20.023)
80C
Length of data
(Bytes=12)
10-11 00 06
Number of read registers
(6)
9-12
?? ??
?? ??
Register data 0
(Pr 20.024)
12-13 47 E4
Start write register
(20.020)
13-16
?? ??
?? ??
Register data 1
(Pr 20.025)
14-15 00 06
Number of write registers
(6)
17-20
?? ??
?? ??
Register data 2
(Pr 20.026)
16 0C
Length of register data to
write
(Bytes=12)
17-20
00 00
30 39
Register data 0
(12345)
21-24
00 00
30 39
Register data 1
(12345)
25-28
00 00
30 39
Register data 2
(12345)

Table of Contents

Other manuals for Emerson Unidrive M400