SI-Ethernet User Guide 19
Issue: 1
Safety
information
Introduction
Mechanical
installation
Electrical
installation
Getting started Parameters
Key features
and Protocols
PC Applications Security Diagnostics
Glossary of
terms
Index
5.9 Set-up flow chart
Start
Connect all drives
together using
approved
cable /
connectors /
switches
Ensure each drive
Is correctly
grounded
Ensure that there
are no circular
loops between
devices/switches
Ensure the correct
cable types are
used
Perform cable
tests
A dedicated
Ethernet cable
tester Is
recommended.
Configure the IP
address, subnet
mask and default
gateway
Ensure PC is on
the same subnet
or the default
gateway on the
drive & PC are set
Ensure segment
lengths no longer
than maximum
limits.
END
See Chapter 4
See Chapter 4
See Chapter 4
See Chapter 4
See Chapter 5
Save module
settings on drive
.
See Chapter 5
Note: Redundant
systems require
specialist hardware.
PING all drives
from a command
prompt to test
connections
See Chapter 5
Any changes
made will require a
module reset to be
activated
Pr
MM.007
= On