Features
Controls
Fail Monitoring
EAOM-36 Manual Start Unit use microprocessor based technology to provide integrated manual start and
fault protection in a wide range of engine applications. The module is housed in 72x72 DIN size.The module is
used to start and stop the engine, indicating the operational status and fault conditions. Automatically shutting
down the engine and indicating the engine failure by a flashing LED. User can control the engine via a two position
key switch and pushbuttons mounted on the front panel or with remote input.
The module has three application feature; 'Generator', 'Pump' or 'Fire Pump'. (can be selected from
parameter P00).
The module can connect directly with engine, thanks to high current relay outputs.
The module has two feature for fuel. One of “energize to run” the other “energize to stop”.
The module protect the engine against fault conditions. If a fault condition occurred, the module indicate the fault
condition and shut-down the engine.
If the key switch is OFF position the module has zero power consumption to save energy. The module energizes
when the key switch position is getting ON position. If Satart button is pressed, the Conf. Out relay output (if selected
preheat output) will activate until the preheat delay is expired.
Press Start button for starting the engine. When engine is running, module will stop the cranking.
Also the module has remote start facility. Please select suitable type of remote start for your application from
program parameters. If remote start input is active the module will start the engine. If remote start is passive the unit will
stop the engine.
The module will check the alarms aftersafety on timer is expired.
Under one of this fault conditions the module will stop the engine;
- Over speed (generator application),
- Under speed(generator application),
- High Temperature,
- Low Oil Pressure,
- Shutdown (if one of conf. input selected shutdown and activated).
To reset the fault, turn the key switch to the OFF position for a few seconds.
The Charge Failure is a warning alarm so the engine continue to work under this failure condition. Also this input
supplying charge alternator excitation current.
Shutdown the engine;
If the engine fuel type is “energize to stop”, press Stop button until the engine comes to rest. After that select OFF
position of the key switch.
If the engine fuel type is “energize to run”, select OFF position of the key switch.
Important note: On the Fire Pump application; If a fault condition occurred, the module will not stop the engine.
The engine will be stopped only when the stop button was pressed or the remote stop signal was detected.
User can select the
feature from program parameters.
Manual and Remote Start Unit with Key Switch, 72x72 DIN Size
Designed For Generator, Pump & Fire Pump Applications
Remote start / stop capability with zero power consumption
Engine start and stop
Automatic shutdown on fault condition
Provides alarm and status information
Alarm and shutdown inputs
Provides charge alternator excitation current
Lamp test function
Oil pressure
Engine temperature
Over speed & Under speed (generator application)
Charging alternator
Conf. Input-1 & 2
Engine fuel or stop solenoid
Starter motor
Preheat, external alarm horn or alarm out
Introduction Brochure. ENG EAOM-36R 01 V00 05/09
START
Hz./
RPM
CHARGING FAIL
~~ ~~
~~~~~~~~
HIGH TEMPERATURE
LOW OIL PRESSURE
FAILED TO START
SPEED
FAILURE
0
I
EAOM - 36
STOP
RPM
Question and Answer IconNeed help?

Do you have a question about the EMKO EAOM-3-STP-ALT and is the answer not in the manual?

EMKO EAOM-3-STP-ALT Specifications

General IconGeneral
MountingDIN rail
Protection classIP20
Output TypeRelay
Number of Outputs3
ProtectionShort-circuit, Overload
Housing MaterialPlastic
Weight150 g
Supply voltage230 V AC
OutputRelay

Summary

Product Features and Functions

Key Features of EAOM-36

Details the unit's capabilities like remote start, auto shutdown, and status information.

Fail Monitoring Parameters

Lists monitored parameters for shutdown: oil pressure, engine temperature, and speed.

Control Functions

Describes control elements like fuel/stop solenoid, starter motor, and preheat outputs.

Program Parameters

Generator Application Parameters

Configuration settings for generator applications, including frequency and speed limits.

Pump (Fire Pump) Application Parameters

Configuration settings for pump applications, focusing on start/stop and safety inputs.

Specifications Overview

General Unit Specifications

Details housing, mounting, protection, environmental rating, and electrical safety requirements.

Outputs and Indicators

Lists relay outputs, failure indicators, and status indicators for monitoring.

Physical Dimensions and Connections

Dimensions and Panel Cut-Out

Provides physical dimensions and panel cut-out details for installation purposes.

Terminal Connection Diagrams

Illustrates terminal connections for EAOM-36.R and EAOM-36.RF models.

Connection Schematics

Schematic Without Remote Start (P16=0)

Wiring diagram for unit operation without utilizing remote start functionality.

Schematic With Remote Signal (P16=1)

Wiring diagram for unit operation when a remote start signal is active.

Advanced Connection Schematics

Schematic With Remote Start (P16=2)

Wiring diagram for remote start operation with zero power consumption.

Fail Safe Connection Schematic

Wiring diagram illustrating the fail-safe operation mode for the unit.

Operation and Product Details

Unit Operation Guide

Explains how to operate the unit using the key switch and control buttons.

Product Codes and Options

Lists different product codes and available options like overspeed sensing.

Related product manuals