48
8. GUEST SCREENS
ENEN
ALARMS TABLE
Type Description Solution
Radiant system temp NOT AVAILABLE
See alarm codes on SMART-MT in the
MIRAI-SMI 4.0 INSTALLATION AND USE
manual
Temp. Inertial storage NOT AVAILABLE
Outside temp Abnormal value of the temp. external air of the HP
Temp. IN H2O Abnormal value of the temp. water inlet of the HP
Temp. OUT H2O Abnormal value of the temp. exit
Sanitary temp water from the HP
HP alarm Abnormal value of the temp. sanitary
Low temp. H2O Alarm from the MAIN PCB of the HP
High temp. H2O
Temp. Value to the imp. too low radiant (risk of con-
densation)
Low flow Water flow rate to the HP too low
Incongruent season Incongruent season (SMART-MT / FEBOS-CRONO)
Incompatible recipe
The loaded recipe is not compatible with the
SMART-MT software version
Load a different recipe.
(e.g. on software versions prior to 4.06 it
is not possible to load recipes 1 and 2)
Low pressure H
2
O NOT AVAILABLE
COM FE alarm
Failure / incorrect communication with FEBOS-
ENERGY
1st Check the connection between
FEBOS-CRONO Maser and FEBOS-
ENERGY.
2nd Replace FEBOS-ENERGY.
3rd Replace the FEBOS-CRONO Master.
COM HP alarm
Lack of / incorrect communication with the SMART-MT
1st Check the connection between
FEBOS- CRONO Master and PCB TERMI-
NAL BLOCK
2nd Replace the SMART-MT.
3rd Replace the FEBOS-CRONO Master.
COM FC alarm
Failure / incorrect communication with the FEBOS-
CRONO Slave
1st Check the connection between
FEBOS- CRONO Master and
PCB TERMINAL BLOCK
2nd Replace the SMART-MT.
3rd Replace the FEBOS-CRONO Master.
Ambient T probe alarm
Abnormal value of the temp. environment detected
by the FEBOS-CRONO
Replace the FEBOS-CRONO
Ambient RH probe alarm
Abnormal value of ambient humidity detected by the
FEBOS-CRONO
Replace the FEBOS-CRONO
8.7 Active alarms
If the icon appears in the top bar , it
means that an alarm is in progress. Pressing
it accesses the Alarms screen. Alarms are
highlighted with red background
es. Active alarm
Allarm COM PdC
Allarm COM FE
GUEST

Other manuals for emmeti FEBOS - CRONO IMX Basic / WiFi