Troubleshooting
© 2017 EMP, Inc. 18
Troubleshooting
Symptom
Check
Pump not running
Check electrical connections.
Check ignition enable wire.
Check if ignition enable wire is “on”.
Verify ignition enable pin location.
Pump is running but not pumping
fluid
Check system fluid level.
Check for tubing restrictions (kinks).
Make sure pump is primed.
Check for collapsed inlet or outlet hose.
Check pump inlet for trapped debris.
No CAN communication and/or
pump not responding to CAN
commands
Check communication harness wiring.
Verify that CAN messages are being transmitted in the proper formats.
Verify that the proper component CAN address is being used.
Suspected water pump seal leak
Reference
Service Bulletin Electric Water Pump Inspection and Diagnostic
Procedures, EMP document 9910085143.
Water pump seal leak
Verify coolant level.
Verify coolant selection (for water seal life OAT, phosphate free, silicate free
coolant is recommended).
Sample coolant and review coolant maintenance records.
Verify system is not aerated (Reference document 9910085145, Fill D&D Test
and Acceptance Criteria).
Check for cavitation or low inlet pressure.
Pump producing excessive noise
Check for cavitation or low inlet pressure.
Check pump inlet for trapped debris.
Check plumbing around pump for valves or components where cavitation may
be occurring.
Check for collapsed inlet hose.