Specifications
© 2017 EMP, Inc. 6
Specifications
Model 12V 24V
Performance
Operating Temperature Maximum (fluid) 203 °F (95 °C) 203 °F (95 °C)
Operating Temperature Minimum (fluid) -40 °F (-40 °C) -40 °F (-40 °C)
Motor Speed Minimum 750 rpm 1000 rpm
Motor Speed Maximum 4600 rpm 4600 rpm
Mechanical
Component Construction Cast Aluminum Cast Aluminum
Component Weight 6.7 lbs (3.03 kg) 6.7 lbs (3.03 kg)
Electrical
Input Voltage 9–16 V DC (14 V nominal) 18–32 V DC (28 V nominal)
Operating Current Draw Maximum 25 A 15 A
Thermal Protection Auto self-protect shutdown Auto self-protect shutdown
Operating Limits
Temperature Limitations
Maximum Fluid and Ambient Operating Temp
Minimum Fluid and Ambient Operating Temp
Maximum Ambient Storage Temp
Minimum Ambient Storage Temp
* If the intended application fluid temperature exceeds 95 °C, the pump
may not perform as expected.
Dimensions and Hole Locations/Bolt Spacing