11/15 EmpirBus Connect-50 User manual Ver. 1.33
1. Press and hold RESET/AUTO for 10 seconds until the display shows “bAS”
2. Press MAN ON/MAN OFF three times. Display now alternates between the current bus ID
and “bAS”.
3. Use the arrow buttons to set the desired bus ID.
4. Press and hold RESET/AUTO for 10 seconds until the DC module restarts.
7.2!Fuse!reset!
A channel with tripped fuse is in normal running mode indicated by a red continuous channel
indicator. To reset the channel to normal operation:
1. Press the right arrow button. ”SEL” will be shown in the display.
2. Use the right arrow button to step to the desired channel.
3. Press and hold RESET/AUTO for two seconds. The fuse is now reset.
4. Press the left arrow until the message “SEL” in the display disappears.
Please note that if the problem that caused the fuse to trip still remains, the fuse will trip again.
7.3!Manual!channel!ov e rr id e!(Not!existing!on!2110000!&!2110001)!
In case of bus failure there is failsafe functionality that allows channels to be manually switched on or
off. For automatic bus failure backup settings, see the Enhanced Limp Home documentation.
A manually switched off channel is in normal running mode indicated by a flashing red channel
indicator.
A manually switched on channel is in normal running mode indicated by a flashing green channel
indicator.
7.3.1!Manual!override!switch!off!
1. Press the right arrow button. ”SEL” will be shown in the display.
2. Use the right arrow button to step to the desired channel.
3. Press and hold MAN ON/MAN OFF for two seconds
4. Press the left arrow until the message “SEL” in the display disappears.
5. Outputs manually switched off are now indicated with flashing red indication.
7.3.2!Manual!override!switch!on!
1. Press the right arrow button. ”SEL” will be shown in the display.
2. Use the right arrow button to step to the desired channel.
3. Press and hold MAN ON/MAN OFF for two seconds
4. If the channel indicator still is flashing red, again press and hold MAN ON/MAN OFF for two
seconds
5. Press the left arrow until the message “SEL” in the display disappears.
6. Outputs manually switched on are now indicated with flashing green indication.
7.3.3!Resetting!a!channel!
1. Press the right arrow button. ”SEL” will be shown in the display.
2. Use the right arrow button to step to the desired channel.
3. Press RESET/AUTO. The channel is now reset.
4. Press the left arrow until the message “SEL” in the display disappears.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EmpirBus Connect-50 and is the answer not in the manual?

EmpirBus Connect-50 Specifications

General IconGeneral
BrandEmpirBus
ModelConnect-50
CategorySwitch
LanguageEnglish

Related product manuals