User’s Manual for Advanced Axial Flux Synchronous Motors and Generators
www.emrax.com Version 4.5 / January 2017 13
EMRAX 208 Technical Data Table (dynamometer test data)
Air cooled = AC
Liquid cooled = LC
Combined cooled = Air + Liquid cooled = CC
Cooling medium specification
(Air Flow = AF; Inlet Water/glycol Flow =
WF; Ambient Air = AA)
If inlet WF temperature and/or AA
temperature are lower, then continuous
power is higher.
WF=8l/min
at 50°C;
AA=25°C
WF=8l/min
at 50°C;
AA=25°C
WF=8l/min
at 50°C;
AA=25°C
WF=8l/min
at 50°C;
AA=25°C
WF=8l/min
at 50°C;
AA=25°C
WF=8l/min
at 50°C;
AA=25°C
Maximal battery voltage [Vdc] and full
load/no load RPM
Peak motor power at max RPM (few min
at cold start / few seconds at hot start)
[kW]
Continuous motor power (at 3000-5000
RPM) depends on the motor RPM [kW]
Maximal rotation speed [RPM]
6000 (7000 peak for a few seconds)
Maximal motor current (for 2 min if cooled
as described in Manual) [Arms]
Continuous motor current [Arms]
Maximal peak motor torque [Nm]
Continuous motor torque [Nm]
Torque / motor current [Nm/1Aph rms]
Maximal temperature of the copper
windings in the stator and max.
temperature of the magnets [°C]
Internal phase resistance at 25 °C [mΩ]
Input phase wire cross-section [mm
2
]
Controller / motor signal
AC voltage between two phases
[Vrms/1RPM]
Specific idle speed (no load RPM)
[RPM/1Vdc]
Specific load speed (depends on the
controller settings) [RPM/1Vdc]
Magnetic field weakening (for higher RPM
at the same power and lower torque) [%]
Magnetic flux – axial [Vs]
Temperature sensor in the motor
Rotor Inertia (mass dia=160mm, m=4,0kg)
[kg*cm²]
Bearings (front:back) - SKF/FAG
6206:6206 (for radial forces) or 6206:7206 (for axial-radial forces; for pull mode; focusing on very high axial load, e.g. for air
propeller) or 6206:3206 (for axial-radial forces; for pull-push mode; »O« orientation, α=25°); other bearings are possible
(exceptionally)