EMRAX 348 Technical Data Table
Technical
data
Type
EMRAX 348
High Voltage
EMRAX 348
Medium Voltage
EMRAX 348
Low Voltage
Air cooled = AC
Liquid cooled = LC
Combined cooled = Air + Liquid cooled = CC
AC
LC
CC
AC
LC
CC
AC
LC
CC
Ingress protection
IP21
IP65
IP21
IP21
IP65
IP21
IP21
IP65
IP21
Cooling medium specification (Air Flow = AF;
Water/glycol Flow = WF if inlet water/glycol
temperature and/or ambient temperature are
lower, then continuous power is higher)
AF=20m/s
; AA=25°C
WF=8l/mi
n at 50°C;
AA=25°C
WF=8l/mi
n at 50°C;
AA=25°C
AF=20m/s
; AA=25°C
WF=8l/mi
n at 50°C;
AA=25°C
WF=8l/mi
n at 50°C;
AA=25°C
AF=20m/s
; AA=25°C
WF=8l/mi
n at 50°C;
AA=25°C
WF=8l/mi
n at 50°C;
AA=25°C
Weight [kg]
39
40
40
39
40
40
39
40
40
Diameter ø / width [mm]
348/107
Maximal battery voltage [Vdc] and full load/no
load RPM
800 Vdc (1800/2200 RPM)
800 Vdc (2800/3400 RPM)
130 Vdc (1200/1500 RPM)
340 Vdc (3200/4000 RPM)
Peak motor power at max RPM (few min at cold
start / few seconds at hot start) [kW]
190
290
125 kW (at 1200 RPM load #)
330 kW (at 3200 RPM load ##)
Continuous motor power at load RPM [kW]
90
100
100
140
150
170
70 at #;
170 at ##
70 at #;
180 at ##
80 at #;
200 at ##
Maximal rotation speed [RPM]
4000 (with maximal battery voltage or magnetic field weakening)
Maximal motor current (for 2 min if it is cooled as
described in Manual) [Arms]
280
450
1100
Continuous motor current [Arms]
140
210
550
Maximal motor torque (for a few seconds) [Nm]
1000
Continuous motor torque [Nm]
500
Torque / motor current [Nm/1Aph rms]
3,8
2,5
0,9
Cogging torque [Nm]
5
Maximal temperature of the copper windings in
the stator and max. temp. of the magnets [°C]
120
Motor efficiency [%]
92 - 98
Internal phase resistance at 25 °C [mΩ]
32
14
5
Input phase wire cross-section [mm
2
]
10,2
15,2
38
Wire connection
star
Induction in Ld/Lq [µH]
418/452
180/195
24,3/26,3
Controller / motor signal
sine wave
AC voltage between two phases [Vrms/1RPM]
0,2320
0,1520
0,0560
Specific idle speed (no load) [RPM/1Vdc]
2,8
4,3
11,8
Specific - load speed (depends on the controller
settings) [RPM/1Vdc]
2,3 2,8
3,5 4,3
9,5 11,8
Magnetic field weakening (for higher RPM at the
same power and lower torque) [%]
up to 100 %
Magnetic flux axial [Vs]
N/A
N/A
N/A
Temperature sensor in the motor
kty 81/210
Number of pole pairs
10
Rotor inertia (mass dia=270 mm, m=20kg)
[kg*cm²]
N/A
Bearings (front:back) SKF/FAG
6009:6009 (for radial forces) for axial-radial forces contact EMRAX Company
*Controller for EMRAX 348 Low Voltage should have very high peak and continuous motor current (1100 Arms peak and 550 Arms continuous). It is difficult to
find such a high current controller in the global market. The most suitable would be the emDrive 500 from the Emsiso Company, which has 500 Arms continuous

Table of Contents

Other manuals for EMRAX 348

Related product manuals