EL – Owner’s Manual – Rev.00 – September 2022 39
4.11.2 PAIRING THE DEVICE TO THE CLOUD
It is time to power on the device for the first time. Switch the breaker at the top of the front panel in
the upper position to switch the device on.
Use the Enapter app to add the device to a site. For detailed information on this, please refer to the
mobile application handbook.
1. If you use the application for the first time, you will need register. If you already have an
account, simply skip this step.
To create an account, click on the create account button of the first screen.
2. After logging in on the Enapter app, create a site – a virtual environment which will house all
the telemetries collected from the devices connected to the cloud via UCMs (Universal
Communication Modules).
3. Add the device to the site by scanning the QR code located on the front panel.
4.11.3 MANUAL FILLING OF ELECTROLYTE
The device is now ready to be commissioned for its first use. Once it is successfully paired to the cloud,
it starts in maintenance mode and prompts to perform the first-time filling.
If refilling the device during regular maintenance, it might be necessary to repeat the steps of draining
and filling the electrolyte a few times. This ensures, that contaminations inside the tank are kept at a
minimum. The Enapter app will automatically guide through the process.
To prepare the electrolyser for operation, before demineralised water is added automatically, it must
be filled with the electrolyte which is included in the shipment. If it is not included, it can typically be
procured or purchased locally. Please refer to Appendix II below.
Warning! Refer to the Material Safety Data Sheet (MSDS) of all chemicals used, before
handling them. All persons using, preparing, and filling the electrolyte into the device
must be informed about any potential hazards involved with their activities.