Deltabar FMD71, FMD72 Description of device parameters
23
Options • No value
• Differential pressure
• Pressure HP
• Pressure LP
• Sensor Temp. HP
• Sensor Temp. LP
• Level before linearization
• Current
• Main measured value (%)
The options depend on the measuring mode chosen.
Factory setting No value
Format 1st Value (004)
Navigation Expert → System → Display → Format 1st Value (004)
Write permission Operators/Service engineers/Expert
Description Specify the number of places after the decimal point for the value displayed in the main
line.
Options • Auto
• x
• x.x
• x.xx
• x.xxx
• x.xxxx
• x.xxxxx
Factory setting Auto
Measuring mode (005/182)
Navigation Expert → Measurement → Measuring Mode (005/182)
Write permission Operators/Service engineers/Expert
Description Select the measuring mode. The operating menu is structured differently depending on the
measuring mode selected.
Options • Pressure
• Level
Note If the measuring mode is changed, no conversion takes place. If necessary, the device has
to be recalibrated after the measuring mode has been changed.
Factory setting Level or according to order specifications