EasyManua.ls Logo

Endress+Hauser Levelflex FMP53 - Mounting; Mounting dimensions

Endress+Hauser Levelflex FMP53
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Levelflex FMP51/52/53/54/55/56/57 XA00644F-A
26 Endress+Hauser
FMP56
Position / 位置 5 (Housing / 外壳 ) = B
Position / 位置 3
(Power Supply; Output /
电源;输出 ) =
Temperature class /
温度组别
P 1 P 2 P 3 P 4 P 5 P 6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
1 canal used /
使用了 1 个槽
T6 ( 85 °C) –40 °C 60 °C 60 °C 60 °C 85 °C 51 °C 85 °C –40 °C –40 °C 40 °C - -
T5 (100 °C) –40 °C 73 °C 73 °C 73 °C 100 °C 66 °C 100 °C –40 °C –40 °C –40 °C - -
T4 (135 °C) –40 °C 73 °C 73 °C 73 °C 120 °C 61 °C 120 °C –40 °C –40 °C –40 °C - -
2 canal used /
使用了 2 个槽
T6 ( 85 °C) –40 °C 56 °C 56 °C 56 °C 85 °C 49 °C 85 °C –40 °C –40 °C 40 °C - -
T5 (100 °C) –40 °C 61 °C 61 °C 61 °C 100 °C 52 °C 100 °C –40 °C –40 °C –40 °C - -
T4 (135 °C) –40 °C 61 °C 61 °C 61 °C 120 °C 48 °C 120 °C –40 °C –40 °C –40 °C - -
Position / 位置 5 (Housing / 外壳 ) = C
Position / 位置 3
(Power Supply; Output /
电源;输出 ) =
Temperature class /
温度组别
P 1 P 2 P 3 P 4 P 5 P 6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
1 canal used /
使用了 1 个槽
T6 ( 85 °C) –40 °C 60 °C 60 °C 60 °C 85 °C 54 °C 85 °C –40 °C –40 °C 40 °C - -
T5 (100 °C) –40 °C 73 °C 73 °C 73 °C 100 °C 67 °C 100 °C –40 °C –40 °C –40 °C - -
T4 (135 °C) –40 °C 73 °C 73 °C 73 °C 120 °C 63 °C 120 °C –40 °C –40 °C –40 °C - -
2 canal used /
使用了 2 个槽
T6 ( 85 °C) –40 °C 56 °C 56 °C 56 °C 85 °C 50 °C 85 °C –40 °C –40 °C 40 °C - -
T5 (100 °C) –40 °C 61 °C 61 °C 61 °C 100 °C 54 °C 100 °C –40 °C –40 °C –40 °C - -
T4 (135 °C) –40 °C 61 °C 61 °C 61 °C 120 °C 50 °C 120 °C –40 °C –40 °C –40 °C - -