XA00644F-A Levelflex FMP51/52/53/54/55/56/57
Endress+Hauser 5
Device type: FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57
Basic specifications
Optional specifications
Position Selected option Description
1, 2 Approval N2 Zone 0/1 Ex ia IIC T6 Ga/Gb,
Zone 20/21 Ex iaD 20/21 T*
3 Power Supply; Output G 2-wire, PROFIBUS PA
4 Display; Operation A
C
Without LCD, via communication
LCD SD02, push button + data backup function
5Housing B
C
Dual compartment, 316L (GT18)
Dual compartment, Alu coated (GT20)
9, 10 Seal AB (only FMP56)
A4 (only FMP51/57)
B3 (only FMP51/56/57)
B5 (only FMP53)
C3 (only FMP51)
C4 (only FMP53)
D1 (only FMP54)
D2 (only FMP54)
Viton, –30...120 °C
Viton, –30...150 °C
EPDM, –40...120 °C
EPDM, FDA, USP Cl. VI, –20..130 °C
Kalrez, –20...200 °C
Kalrez, FDA, USP Cl. VI, –20...150 °C
Graphite, –196...280 °C (XT)
Graphite, –196...450 °C (HT)
ID Selected option Description
Mx Probe Design MA (only FMP53)
MB
MC (only FMP53)
ME (only FMP51/54)
Sensor compact, detachable
Sensor remote, 3 m/9 ft cable, detachable +
mounting bracket
Sensor remote, 6 m/18 ft cable, detachable +
mounting bracket
Coax ground tube multiple punched
Nx Accessory Mounted NC (only FMP51/52/55) Gas-tight feed through