EasyManua.ls Logo

Endress+Hauser Levelflex FMP57 - Page 197

Endress+Hauser Levelflex FMP57
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Levelflex FMP56, FMP57 FOUNDATION Fieldbus Operating menu
Endress+Hauser 197
Logging interval
Navigation  Diagnostics → Data logging → Logging interval
Description Define logging interval t
log
.
User entry 1.0 to 3 600.0 s
Factory setting 30.0 s
Additional information This parameter defines the interval between the individual data points in the data log, and
thus the maximum loggable process time T
log
:
If 1 logging channel is used: T
log
= 1000 ⋅ t
log
If 2 logging channels are used: T
log
= 500 ⋅ t
log
If 3 logging channels are used: T
log
= 333 ⋅ t
log
If 4 logging channels are used: T
log
= 250 ⋅ t
log
Once this time elapses, the oldest data points in the data log are cyclically overwritten such
that a time of T
log
always remains in the memory (ring memory principle).
The logged data are deleted if this parameter is changed.
Example
When using 1 logging channel
T
log
= 1000 ⋅ 1 s = 1 000 s ≈ 16.5 min
T
log
= 1000 ⋅ 10 s = 1 000 s ≈ 2.75 h
T
log
= 1000 ⋅ 80 s = 80 000 s ≈ 22 h
T
log
= 1000 ⋅ 3 600 s = 3 600 000 s ≈ 41 d
Clear logging data
Navigation  Diagnostics → Data logging → Clear logging
Description Initiate a deletion of the complete logging memory.
Selection Cancel
Clear data
Factory setting Cancel