Micropilot FMR67B HART Installation
Endress+Hauser 13
10.3.3 Drip-off antenna PTFE 50 mm (2 in)
Information concerning threaded connections
When screwing in, turn by the hex bolt only.
Tool: open-ended wrench 55 mm
Maximum permissible torque: 50 Nm (36 lbf ft)
Information about the mounting nozzle
The maximum nozzle length H
max
depends on the nozzle diameter D.
Maximum nozzle length H
max
as a function of the nozzle diameter D
D H
max
H
øD
max
50 to 80 mm (2 to 3.2 in) 750 mm (30 in)
80 to 100 mm (3.2 to 4 in) 1 150 mm (46 in)
100 to 150 mm (4 to 6 in) 1 450 mm (58 in)
≥150 mm (6 in) 2 200 mm (88 in)
In the case of longer nozzles, reduced measuring performance must be expected.
Please note the following:
The end of the nozzle must be smooth and free from burrs.
The edge of the nozzle should be rounded.
Mapping must be performed.
Please contact the manufacturer's support department for applications with nozzles
that are higher than indicated in the table.
10.3.4 Antenna, flush mount 80 mm (3 in)
Information about the mounting nozzle
The maximum nozzle length H
max
depends on the nozzle diameter D.