Installation Nivotester FTL325P, 3-channel
10 Endress+Hauser
5 Installation
5.1 Mounting conditions
If using outside the hazardous area, mount the device in a cabinet.
Mount the device so that it is protected against weather and impact.
If operating outdoors and in warmer climates, avoid direct sunlight.
Protective housing (IP65) is available for up to four single-channel Nivotester devices or
two 3-channel Nivotester devices.
5.2 Mounting the measuring device
5.2.1 Horizontal orientation
A
50 (2)
£
7.5 (0.3)
15 (0.59)
50 (2)
£
50 (2)
£
B
-
-
.
A0026303
 3 Minimum spacing, horizontal orientation. Unit of measurement mm (in)
A Connection of another device type
B DIN rail in accordance with EN 60715 TH35-7.5/15
A horizontal installation ensures better dissipation of heat than a vertical orientation.