EasyManuals Logo

Endress+Hauser prosonic flow 92 Technical Information

Endress+Hauser prosonic flow 92
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Technical Information
TI 060D/06/en
50102085
Portable Ultrasonic Flow Measuring
System
prosonic flow 92
Temporary volume flow measurement of liquids
with “Clamp On” sensors
Features and benefits
Portable transmitter, battery operated,
for temporary measurements
Built-in data logger with a capacity of
40000 measuring values
Site Setup operating menus for
straightforward commissioning of up to
20 measurement sites
“Clamp On” sensors, non-contact
measurement technique
The sensors are affixed to the piping
from the outside
Very wide range of nominal diameters
Sensors U DN 15...100
Sensors W DN 50...4000
Wide temperature range of
–20…+80 °C
Measuring transmitter in protected
handheld housing in: IP 50
Sensors U in: IP 52
Sensors W in:
IP 67 Sensorbody
IP 52 BNC adapter
Interfaces
Data readout software for use with a
personal computer
Current in- and outputs (4...20 mA)
Application
Ideally suited for temporary, bidirectional
measurement of pure or slightly soiled
liquids with a gas content of < 1% or a
solids content of < 5%.
Application examples:
Water, wastewater etc.
Ultrapure water with low conductivity
Process facilities
The “Clamp On” sensors are equally
suitable for homogeneous piping as for
piping made of composite materials:
steel, plastic, GRP and glass pipes
Lined pipes

Other manuals for Endress+Hauser prosonic flow 92

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser prosonic flow 92 and is the answer not in the manual?

Endress+Hauser prosonic flow 92 Specifications

General IconGeneral
BrandEndress+Hauser
Modelprosonic flow 92
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals