Device type | Ultrasonic flowmeter |
---|---|
Enclosure material | Aluminum, stainless steel |
Housing Material | Aluminum, stainless steel |
Ingress protection | IP66/67 |
Measurement Principle | Transit-time difference |
Accuracy | ±0.5 % of the measured value |
Repeatability | ±0.15% of reading ±0.005 m/s (±0.015 ft/s) |
Temperature Range | -40 to +60 °C |
Process Temperature | -40°C to +200°C |
Process Pressure | Max. 40 bar (580 psi) |
Output | 4 to 20 mA, pulse, frequency |
Communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
Power Supply | 24 V DC |
Process Connection | Flanged, threaded |
Approvals | ATEX, IECEx |
Protection Class | NEMA 4X |
Specifies the intended application and limitations of the measuring device.
Outlines requirements for safe installation, commissioning, and operation.
Details safety considerations for operational use and compliance.
Describes the necessary steps for returning a device for repair or calibration.
Explains the meaning of safety symbols and conventions used in the manual.
Defines the components of the Prosonic Flow 93 system.
Details the specifications found on the transmitter's nameplate.
Provides specifications for the Prosonic Flow P measuring sensor.
Lists specifications for the Prosonic Flow U sensors.
Confirms compliance with EC Directives and safety standards.
Details the certification status for PROFIBUS-DP/-PA.
Lists registered trademarks associated with the product and technology.
Guidelines for receiving, transporting, and storing the device.
Specifies environmental and site requirements for installation.
Guidance on the recommended mounting orientation of the sensors.
Requirements for upstream and downstream pipe sections for clamp-on sensors.
Requirements for upstream and downstream pipe sections for insertion sensors.
Information on available lengths for sensor connecting cables.
Detailed steps for installing various sensors and components.
Checklist for verifying correct installation after completion.
Details cable requirements for PROFIBUS-DP and PROFIBUS-PA.
Procedure for connecting sensor cables to the transmitter.
Steps for connecting the transmitter to power and PROFIBUS.
Overview of terminal connections for the transmitter.
Details on the PROFIBUS-PA fieldbus connector.
Information regarding potential equalisation requirements.
Specifies the IP ratings for transmitter and sensors.
Checklist for verifying electrical connections after installation.
Overview of options for configuring and commissioning the device.
Instructions for operating the device using its local display.
Description of the display layout and control elements.
Step-by-step guide to navigating and using the function matrix.
Explanation of error types, codes, and display messages.
Overview of PROFIBUS-DP and PROFIBUS-PA technology.
Diagram and explanation of the PROFIBUS-DP system architecture.
Diagram and explanation of the PROFIBUS-PA system architecture.
Details on transmitting parameters during maintenance or for display.
Using external software for device configuration.
Description of the FieldTool service and configuration software.
Details on the Commuwin II software for remote operation.
Settings for hardware configuration, including write protection.
Instructions on enabling or disabling hardware write protection via jumpers.
Methods for configuring the device's PROFIBUS address.
Ensures all pre-startup checks are completed before operation.
Guides for configuring the device using its local display interface.
Procedure for determining sensor distance using the Quick Setup menu.
Steps for initial device setup and parameter configuration.
Step-by-step guide for commissioning via the local display.
Using external software for device commissioning and setup.
Methods for sensor installation using configuration software.
Detailed steps for configuring the BUS interface using Commuwin II.
Procedure for scaling input values in Analog Input function blocks.
Information on integrating the device into a PROFIBUS-DP system.
Details on the structure and data format for cyclic data transmission.
Practical examples of device configuration using specific software.
Procedures for commissioning based on specific application needs.
Steps for performing zero point adjustment for accuracy.
Information on data storage devices like T-DAT and F-Chip.
General notes on maintenance requirements for the system.
Guidelines for cleaning the exterior of the device.
Information on the use and application of coupling fluid.
List of available accessories for the transmitter and sensors.
General guide to diagnosing and resolving faults.
Steps to diagnose issues based on display status.
Explanation of error icons and message types.
Detailed table of system and process errors and their causes/remedies.
Troubleshooting steps for process issues not indicated by error messages.
Information on available spare parts for the transmitter.
Procedure for safely installing and removing electronic boards.
Steps for replacing the active part of the insertion sensor.
Instructions for safely replacing the device fuse.
Overview of software versions and associated changes.
Summary of key technical specifications.
Description of the measuring device's intended applications.
Details on the measuring principle and system components.
Specifications for measured variables and measuring ranges.
Details on output signals and data transmission for PROFIBUS.
Electrical connection and supply voltage requirements.
Information on measurement accuracy and repeatability.
Specifies environmental and installation operating conditions.
Details on the physical design and materials used.
Description of the display elements and operating controls.
Listing of certifications and regulatory compliance.
Guidance on obtaining detailed ordering information.
List of available accessories and their ordering details.
List of related documentation and information resources.
Detailed dimensions for the wall-mount transmitter housing.
Dimensional data for Prosonic Flow P sensors.
Dimensional data for Prosonic Flow W clamp-on sensors.
Dimensional data for Prosonic Flow U clamp-on sensors.
Dimensional data for Prosonic Flow W insertion sensors.