3 Installation PROline Prosonic Flow 93 PROFIBUS-DP/-PA
38 Endress+Hauser
3.3.12 Installing the wall-mount transmitter housing
There are various ways of installing the wall-mount housing:
Direct wall mounting
Panel mounting (with separate mounting set, accessoriesPage 119)
Pipe mounting (with separate mounting set, accessoriesPage 119)
"
Caution!
Make sure that ambient temperature does not exceed the permissible range
(–20...+60 °C). Install the device in a shady location. Avoid direct sunlight.
Always install the wall-mount housing in such a way that the cable entries are pointing
down.
Direct wall mounting
1. Drill the holes as illustrated in Fig. 43.
2. Remove the cover of the connection compartment (a).
3. Push the two securing screws (b) through the appropriate bores (c) in the housing.
– Securing screws (M6): max. Ø 6.5 mm
– Screw head: max. Ø 10.5 mm
4. Secure the transmitter housing to the wall as indicated.
5. Screw the cover of the connection compartment (a) firmly onto the housing.
Fig. 43: Direct wall mounting
90
35
a
b
192
81.5
c
c
F06-xxxxxxxx-17-03-xx-xx-000