EasyManua.ls Logo

Endress+Hauser Proline Prosonic Flow 93 - Fieldbus Connector

Endress+Hauser Proline Prosonic Flow 93
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 Wiring PROline Prosonic Flow 93 PROFIBUS-DP/-PA
50 Endress+Hauser
4.3.3 Fieldbus connector
!
Note!
This connector can only be used for a PROFIBUS-PA device.
The connection technology of PROFIBUS-PA allows measuring devices to be
connected to the fieldbus via uniform mechanical connections such as T-boxes,
junction boxes, etc. This connection technology using prefabricated distribution
modules and plug-in connectors offers substantial advantages over conventional
wiring:
Field devices can be removed, replaced or added at any time during normal
operation. The communications will not be interrupted.
This simplifies installation and maintenance significantly.
Existing cable infrastructures can be used and expanded instantly, e.g. when
constructing new star distributors using 4-channel or 8-channel junction boxes.
Prosonic Flow 93 can therefore be supplied with the option of a ready-mounted fieldbus
connector. Fieldbus connectors for retrofitting can be ordered from E+H as a spare part
(see Page 119).
Fig. 50: Connectors for connecting to the PROFIBUS-PA
A = Wall-mount housing
B = Protection cap for connector
C = Fieldbus conector
D = Adapter PG 13.5 / M 20.5
E = Connector on housing (male)
F = Connector (female)
Pin assignment / colour codes:
1 = Brown wire: PA+ (terminal 26)
2 = Not connected
3 = Blue wire: PA (terminal 27)
4 = Black wire: ground (notes on connection
Page 49)
5 = Female connector in centre not assigned
6 = Positioning groove
7 = Positioning key
B
C
D
150/300 mm
45.0 mm
(1.766")
PG 13.5
M 12 x 1
AE
F
Esc
E
-
+
4
1
2
3
7
34
21
5
6
F06-xxxPBxxx-04-xx-xx-xx-001