EasyManua.ls Logo

Endress+Hauser Proline Prosonic Flow 93 - Technical Data; Technical Data at a Glance; Application; Function and System Design

Endress+Hauser Proline Prosonic Flow 93
162 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PROline Prosonic Flow 93 PROFIBUS-DP/-PA 10 Technical data
Endress+Hauser 143
10 Technical data
10.1 Technical data at a glance
10.1.1 Application
Measuring the flow rate of liquids in closed piping systems.
Applications in measuring, control and regulation technology for monitoring
processes.
10.1.2 Function and system design
Measuring principle Prosonic Flow operates on the principle of transit time difference.
Measuring system The measuring system consists of a transmitter and measuring sensors.
Two versions are available:
Version for installation in the safe zone and for Ex Zone 2
Version for installation in Ex Zone 1 (see separate additional Ex documentation)
Transmitter:
Prosonic Flow 93 PROFIBUS-DP/-PA
Measuring sensors:
Prosonic Flow P (for chemical and process applications)
for nominal diameters DN 50...4000
Prosonic Flow W Clamp On version (water/wastewater applications)
for nominal diameters DN 50...4000
Prosonic Flow U Clamp On version (water/ultra pure water applications)
for nominal diameters DN 15...100
dedicated for plastic pipes
Prosonic Flow W Insertion version (water/wastewater applications)
for nominal diameters DN 200...4000
Prosonic Flow DDU 18 sound velocity measuring sensors
for nominal diameters DN 50...3000
Prosonic Flow DDU 19 wall thickness measuring sensor
for wall thicknesses of 2...50 mm for steel pipes and
for wall thicknesses of 4...15 mm for plastic pipes (for limited service at PTFE
or PE pipes)

Table of Contents

Other manuals for Endress+Hauser Proline Prosonic Flow 93

Related product manuals