PROline Prosonic Flow 93 PROFIBUS-DP/-PA 2 Identification
Endress+Hauser 11
2.1.3 Nameplate of the Prosonic Flow U sensors
Fig. 3: Nameplate specifications for the “Prosonic Flow U” sensors (example)
1 Ordering code / serial number: See the specifications on the order confirmation for the meanings of the
individual letters and digits.
2 Sensor type
3 Range of nominal diameters: DN 15...100
4 Max. fluid temperature range: -20 °C (-4 °F) ... +80 °C (+175 °F)
5 Degree of protection
6 Ambient temperature range: -20 °C (-4 °F) ... +60 °C (+140 °F)
7 Data on explosion protection
Refer to the specific additional Ex documentation for detailed information. Please do not hesitate to con-
tact your E+H sales office if you have any questions.
2.2 CE mark, declaration of conformity
The devices are designed to meet state-of-the-art safety requirements, have been
tested and left the factory in a condition in which they are safe to operate. The devices
comply with the applicable standards and regulations in accordance with EN 61010
“Protection Measures for Electrical Equipment for Measurement, Control, Regulation
and Laboratory Procedures” and with the EMC requirements of EN 61326/A1.
The measuring system described in these Operating Instructions thus complies with the
statutory requirements of the EC Directives. Endress+Hauser confirms successful
testing of the device by affixing the CE mark.
2.3 Device certification PROFIBUS-DP/-PA
The Prosonic Flow 93 flowmeter has passed all the test procedures implemented and
has been certified and registered by the PNO (PROFIBUS User Organisation). The
flowmeter thus meets all the requirements of the specifications listed below:
Certified for PROFIBUS Profile 3.0
Device certification number: available upon request
The instrument meets all of the PROFIBUS Profile 3.0 Specifications.
The device may also be operated using certified devices from other manufacturers
(interoperability).
1
2
4
6
7
5
3
DN15 - DN100
-20°C (-4°F) ... +60°C (+140°F)
-20°C (-4°F) ... +80°C (+175°F)
T amb.:
TM:
Type: U-CL-2F-L-A
i
IP52
CH 1
Order Code:
PROSONIC FLOW U
ENDRESS+HAUSER
Ser.No.:
93UA1-XXXXXXXXXXXX
12345678901
For Installation refer to control dwg. of transmitter
CL.I, Div.2, GP. ABCD
CL.I, Zone 2 IIC T6-T1
APPROVED
FM
F06-9xUxxxxx-18-05-xx-xx-001

Table of Contents

Other manuals for Endress+Hauser Proline Prosonic Flow 93

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Proline Prosonic Flow 93 and is the answer not in the manual?

Endress+Hauser Proline Prosonic Flow 93 Specifications

General IconGeneral
BrandEndress+Hauser
ModelProline Prosonic Flow 93
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals