Summary

Operating Instructions

Safety Instructions

Designated Use

Defines the intended purpose and scope of the measuring device for gas flow measurement.

Installation, Commissioning, and Operation Safety

Outlines safety requirements for installation, setup, and use of the device by trained personnel.

Operational Safety

Covers safety aspects during operation, including handling hazardous environments and high temperatures.

Device Return Procedures

Provides instructions and precautions for returning the device, including decontamination.

Safety Conventions and Icons

Explains the meaning of safety symbols (Warning, Caution, Note) used in the manual.

Identification

Device Designation

Details the components and available versions (compact/remote) of the t-mass 65 system.

Transmitter Nameplate

Describes the information found on the transmitter's nameplate.

Sensor Nameplate

Describes the information found on the sensor's nameplate.

Connection Nameplate

Details the nameplate specifications for transmitter connections.

Certificates and Approvals

Lists certifications and approvals obtained by the measuring system, including CE and PROFIBUS.

Registered Trademarks

Lists registered trademarks associated with the product and company.

Installation

Incoming Acceptance, Transport, and Storage

Covers initial checks, transport guidelines, and storage recommendations for the device.

Installation Conditions

Details environmental and pipework requirements for proper installation, sensitive to flow conditions.

Pipework Requirements

Specifies requirements for pipework, welding, and flange connections for correct installation.

Sensor Orientation

Guides on correct sensor orientation relative to the flow direction for accurate measurement.

Inlet and Outlet Runs

Outlines recommended inlet and outlet pipe lengths to ensure optimal measurement accuracy.

Heating and Insulation

Discusses measures for avoiding heat loss and condensation, and insulating the device.

Vibration Considerations

Warns about potential mechanical damage from excessive vibrations and advises checking specifications.

Installation Instructions

Provides step-by-step instructions for installing the sensor and transmitter.

Mounting Insertion Sensor

Details the process of mounting the insertion sensor using a welding socket.

Removing Insertion Sensor

Explains the procedure for safely removing the insertion sensor, including safety warnings.

Mounting Flanged Sensor

Guides on mounting the flanged sensor, ensuring correct flow direction alignment.

Turning Transmitter Housing

Describes how to rotate the transmitter housing for optimal positioning and access.

Turning Local Display

Explains how to adjust the orientation of the local display module.

Wall-Mount Housing Installation

Covers different methods for installing the wall-mount transmitter housing.

Post-Installation Checks

Lists essential checks to perform after installing the measuring device.

Wiring

Cable Specifications

Details technical specifications for cables used in PROFIBUS DP connections.

PROFIBUS DP Cable Specifications

Provides specific cable type information, bus structure, and transmission rates for PROFIBUS DP.

Shielding and Grounding

Covers crucial aspects of shielding and grounding for ensuring electromagnetic compatibility.

Connecting Remote Version

Explains how to connect the remote sensor and transmitter, including cable specifications.

Sensor/Transmitter Cable Connection

Step-by-step guide for connecting the sensor and transmitter cables in remote versions.

Connecting Cable Specification

Lists the specifications for the connecting cable used in remote versions.

Connecting the Measuring Unit

Details the process of connecting the main measuring unit, including safety precautions.

Terminal Assignment

Shows the terminal assignments for PROFIBUS DP and PROFIBUS PA devices.

Transmitter Connection

Guides on connecting the transmitter, including safety precautions and wiring diagrams.

PROFIBUS DP Connection Diagram

Illustrates the connection diagram for PROFIBUS DP interface.

PROFIBUS PA Connection Diagram

Illustrates the connection diagram for PROFIBUS PA interface.

Degree of Protection

Explains requirements to maintain the device's IP 67 (NEMA 4X) protection.

Post-Connection Checks

Lists essential electrical connection checks to perform after completing wiring.

Operation

Quick Operation Guide

Provides an overview of options for configuring and commissioning the device.

Local Display Overview

Describes the device's local display for field operation and parameter configuration.

Display and Operating Elements

Details the components of the local display and how to use them for navigation and input.

Icons

Explains the meaning of icons used on the device's display for status and error indication.

Function Matrix Instructions

Guides on navigating and using the device's function matrix for configuration.

General Function Matrix Notes

Provides general notes and guidelines for using the function matrix and configuration.

Programming Mode Management

Explains how to enable, disable, and use the programming mode with security codes.

Error Messages

Covers system and process errors, their types, and display indicators.

Error Message Types

Explains the classification of errors into notice and fault messages.

Operating Options

Lists various software and tools for operating and configuring the device.

FieldCare

Introduces FieldCare as an asset management tool for device configuration and diagnosis.

SIMATIC PDM

Describes SIMATIC PDM as a standardized tool for device operation and configuration.

Device Description Files

Lists available device description files and sources for PROFIBUS DP and PA.

PROFIBUS DP Hardware Settings

Details hardware configuration steps for PROFIBUS DP devices.

Configure Write Protection

Explains how to enable or disable hardware write protection via jumpers.

Configure Device Address

Guides on setting the device address using miniature switches or software.

Configure Terminating Resistors

Covers the proper configuration of terminating resistors for RS485 lines.

PROFIBUS PA Hardware Settings

Details hardware configuration steps for PROFIBUS PA devices.

Configure Write Protection (PA)

Explains how to enable or disable hardware write protection for PROFIBUS PA.

Configure Device Address (PA)

Guides on setting the device address for PROFIBUS PA using miniature switches.

Commissioning

Function Check

Emphasizes completing final checks before starting up the measuring point.

Switching on the Device

Describes the process of powering on the device and its self-test sequence.

Quick Setup Overview

Introduces the Quick Setup menu for fast configuration of standard parameters.

Quick Setup: Commissioning

Details the steps for the "Commissioning" Quick Setup menu for device setup.

Quick Setup: Sensor Configuration

Guides on setting up the insertion sensor according to pipe and depth calculations.

Quick Setup: Gas Configuration

Explains how to configure gas groups for different gas streams for accurate measurement.

Quick Setup: Pressure Configuration

Details programming the process pressure for each gas group for accurate readings.

Quick Setup: Heat Flow Configuration

Guides on programming heating value calculation methods for fuel gases.

Quick Setup: Communication Configuration

Covers configuration for establishing cyclic data transfer via PROFIBUS.

Data Backup and Transmission

Explains how to transfer data between T-DAT and EEPROM for backup or replacement.

PROFIBUS Interface Commissioning

Outlines the overall steps for commissioning the PROFIBUS interface.

PROFIBUS DP/PA Commissioning Steps

Provides a sequence of steps for commissioning PROFIBUS DP/PA interfaces.

PROFIBUS DP/PA System Integration

Covers integrating the device into a PROFIBUS DP/PA system using GSD files.

Device Master File (GSD File)

Explains the role and types of GSD files needed for PROFIBUS configuration.

Selecting the GSD File Example

Provides an example of selecting a GSD file for PROFIBUS PA configuration.

Maximum Number of Writes

Warns about the limitation on EEPROM writes to prevent data loss.

PROFIBUS DP Cyclic Data Transmission

Describes cyclic data transmission for PROFIBUS DP using the GSD file.

PROFIBUS DP Block Model

Illustrates the block model for PROFIBUS DP cyclic data transmission.

PROFIBUS DP Modules for Cyclic Data

Details the modules available for cyclic data transmission in PROFIBUS DP.

PROFIBUS DP Module Descriptions

Provides descriptions for Analog Input (AI) and TOTAL modules in PROFIBUS DP.

PROFIBUS DP Configuration Examples

Shows configuration examples using Simatic S7 HW-Konfig for PROFIBUS DP.

PROFIBUS PA Cyclic Data Transmission

Describes cyclic data transmission for PROFIBUS PA using the GSD file.

PROFIBUS PA Block Model

Illustrates the block model for PROFIBUS PA cyclic data transmission.

PROFIBUS PA Modules for Cyclic Data

Details the modules available for cyclic data transmission in PROFIBUS PA.

PROFIBUS PA Module Descriptions

Provides descriptions for Analog Input (AI) and TOTAL modules for PROFIBUS PA.

PROFIBUS PA Configuration Examples

Shows configuration examples using Simatic S7 HW-Konfig for PROFIBUS PA.

PROFIBUS DP/PA Acyclic Data Transmission

Master Class 2 Acyclic (MS2AC)

Details MS2AC communication for acyclic data transfer between device and master.

Master Class 1 Acyclic (MS1AC)

Explains MS1AC communication, noting limitations and impact on service life.

Adjustment

Zero Point Adjustment

Explains how to perform zero point adjustment under process conditions for accuracy.

Data Storage Device (HistoROM)

HistoROM/S-DAT (Sensor-DAT)

Describes the HistoROM/S-DAT for storing sensor-specific parameters.

HistoROM/T-DAT (Transmitter-DAT)

Describes the HistoROM/T-DAT for storing transmitter parameters and settings.

Maintenance

External Cleaning

Provides guidelines for cleaning the exterior of the measuring device safely.

Pipe Cleaning

Describes procedures for in-situ pipe and sensor cleaning, noting potential effects.

Transducer Cleaning

Advises on cleaning the sensor to minimize measurement errors due to contamination.

Replacing Seals

Explains when and how to replace seals on the sensor, with specific information.

In-situ Calibration

Details requirements for supporting in-situ calibration with adjustment to save time and cost.

Recalibration

Discusses determining recalibration intervals based on application and gas conditions.

Accessories

Device-Specific Accessories

Lists accessories specific to the t-mass 65 transmitter and sensor.

Measuring Principle-Specific Accessories

Lists accessories related to the thermal dispersion measuring principle.

Service-Specific Accessories

Lists accessories for device service, testing, and configuration.

Trouble-shooting

Trouble-shooting Instructions

Provides a checklist for diagnosing and resolving faults after commissioning or during operation.

Display Checks

Guides on checking the display and output signals when no readings are visible.

Error Messages on Display

Explains how errors are displayed, including icons, types, and error codes.

Faulty Connection to PROFIBUS Master

Covers checks for establishing a connection between the PROFIBUS Master and the device.

System Error Messages

Explains system errors, their recognition as fault messages, and display indicators.

Displaying Device Status on PROFIBUS DP

Details how to query device status using operating programs like FieldCare.

List of System Error Messages

Provides a detailed list of system error messages, their causes, and remedies.

Process Error Messages

Covers process errors, their display, and potential rectification steps.

List of Process Error Messages

Lists specific process error messages, their causes, and remedies.

Process Errors Without Messages

Describes symptoms and rectification for errors that do not display specific messages.

Spare Parts

Lists available spare parts for device repair and component replacement.

Removing and Installing Printed Circuit Boards (Field Housing)

Provides instructions for removing and installing printed circuit boards in the field housing.

Removing and Installing Printed Circuit Boards (Wall-Mount Housing)

Instructions for removing and installing circuit boards in the wall-mount housing.

Removing and Installing Printed Circuit Boards (Sensor Remote Version)

Instructions for removing and installing circuit boards in the sensor remote housing.

Replacing Device Fuse

Details the procedure for replacing the device fuse on the power unit board.

Device Return

Outlines procedures for returning a device for repair or calibration.

Disposal

Advises observing local regulations for device disposal.

Software History

Provides a history of software versions and their changes.

Technical Data

Technical Data at a Glance

Provides a summary of key technical specifications for the measuring device.

Applications

Defines the intended applications and limitations of the measuring device.

Function and System Design

Describes the measuring principle and system design of the t-mass 65.

Input Specifications

Details measured variables and factors affecting the measuring range.

Output Specifications

Lists the output signals and data available via PROFIBUS DP and PA interfaces.

Power Supply Details

Details electrical connections, supply voltage, power consumption, and failure behavior.

Performance Characteristics

Covers calibration conditions, maximum error, repeatability, and response time.

Operating Conditions: Installation

Specifies conditions related to installation, pipe runs, and cable length.

Operating Conditions: Environment

Details environmental conditions like ambient temperature and degree of protection.

Operating Conditions: Process

Outlines process conditions including medium temperature, pressure, and flow limits.

Mechanical Construction

Provides information on weight, materials, and dimensions of the device.

Human Interface

Describes the display elements, operating elements, and languages supported.

Certificates and Approvals

Lists CE mark, C-Tick mark, Ex approval, and PROFIBUS certification.

Ordering Information

Refers to Endress+Hauser representatives for detailed ordering information.

Accessories

Lists available accessories for the transmitter and sensor.

Documentation

Lists related technical documentation and manuals for further reference.