Battery Charger RLD
User's Manual
SYMPTOM POSSIBLE CAUSES ACTION
Charger
too noisy
G
1 Bad contactor. Replace contactor and freewheeling diode.
2 One or more diodes shorted. Replace rectifier.
Battery has low
S.G. and/or
doesn't
last full shift
H
1 Wrong AC input settings. Adjust AC input settings to lower voltage.
2 Battery capacity too low. Replace battery.
Battery
temperature
too high.
I
1 Wrong AC input settings. Adjust AC input settings to higher voltage.
2 Battery power demand too high. Consider purchasing bigger Ah battery.
3 Insufficient cool down time.
Increase cool down time before/after
charging.
4 Automatic stop doesn't work. Check and replace board and/or contactor.
OWM-AR-D-[] Page 23 of 23