7. MAINTENANCE
7.1. Safety instructions for the repair of the product
The high frequency charger requires a minimum of maintenance.
When carrying out maintenance on the battery or the high frequency charger, it is strongly
recommended to wear full body protection such as safety glasses, safety suit, safety shoes
and safety gloves. If you do come into contact with battery acid, follow the instructions in
chapter 11.5.
Repairs to the product may only be carried out by a qualified service technician and
according to the manufacturer’s instructions.
No modifications or alterations to this high frequency charger which may affect capacity,
stability or safety requirements of the high frequency charger but not limited to these
examples, shall be made without the prior written approval of the original manufacturer,
its authorized representative, or a successor thereof.
Do not open the cabinet. Only qualified personnel can open this.
7. 2 . Maintenance schedule
Task 2H D W M 6M Y
1. Inspect the cables
2. Check the connections to the battery terminals
3. Check all the ventilation slots for obstructions
2H: every 2 hours, D: daily, W: weekly, M: monthly, 6M: every 6 months, Y: yearly
A daily maintenance check can limit wear to a minimum.
Make sure that the instruction manual is complete, legible and available for reference.
Check the complete high frequency charger for damage, corrosion or cracks in structural
components.
7. 3. Maintenance instructions
1. Inspect the cables
If you see that the main line is damaged, carefully remove the plug and remove the product from
service.
Continuing to work with the device can lead to electrocution, resulting in serious injury or
death.
This maintenance may be carried out by the operator.
2. Check the connections to the battery terminals
Make sure the connections for charging the batteries are tight and clean. Loose connections, scorched
or damaged cables and/or pipes must be repaired immediately.
This maintenance may be carried out by the operator.