31
Enphase IQ7-60-2-US Microinverter Parameters
Topic
Unit
Min
Typical
Max
AC short circuit fault current over 3 cycles
A rms for over 3
cycles
5.8 Arms
High AC voltage trip limit accuracy
mVrms
280
Low AC voltage trip limit accuracy
mVrms
179
Frequency trip limit accuracy
%
±0.1
Trip time accuracy
milliseconds
±0.1% or 2 cycles
Overvoltage class AC port
III
AC port backfeed under single fault
A
0
Power factor setting
1.0
Miscellaneous Parameters
Maximum
3
microinverters per 20A (max) AC branch circuit
240 VAC (single phase)
208 VAC (single phase)
16
13
CEC weighted efficiency
240 VAC (single phase)
208 VAC (single phase)
%
97.0
96.5
Static MPPT efficiency (weighted, ref EN 50530)
%
99.0
Total harmonic distortion
%
5
Ambient temperature range
C
-40
+65
Night tare loss
mW
50
Storage temperature range
C
-40
+85
Features and Specifications
Compatibility
Pairs with most 60-cell/120 half-cell PV modules.
Dimensions not including mounting bracket
212 mm x 175 mm x 30.2 mm (approximate)
Connector type
MC-4 connector
Weight
1.08 kg (2.38 lbs.)
Environmental category / UV exposure rating
NEMA type 6 / outdoor
Torque specifications for fasteners
(Do not over torque)
6 mm (1/4”) mounting hardware: 5 N m (45 to 50 in-lbs.)
8 mm (5/16”) mounting hardware: 9 N m (80 to 85 in-
lbs.)
When using UL 2703 mounting hardware, use the
manufacturer’s recommended torque value
Cooling
Natural convection - no fans
Relative humidity range
4% to 100% condensing
Approved for wet locations
Yes
Pollution degree
PD3
3
Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
.

Table of Contents