IQ 7 / IQ 7+ / IQ 7X / IQ 7A Micro Installation and Operation
© 2020 Enphase Energy Inc. All rights reserved. 141-00043-03
Enphase IQ7-60-2-US Microinverter Parameters
AC short circuit fault current over 3 cycles
High AC voltage trip limit accuracy
Low AC voltage trip limit accuracy
Frequency trip limit accuracy
Overvoltage class AC port
AC port backfeed under single fault
Maximum
3
microinverters per 20A (max) AC branch circuit
240 VAC (single phase)
208 VAC (single phase)
CEC weighted efficiency
240 VAC (single phase)
208 VAC (single phase)
Static MPPT efficiency (weighted, ref EN 50530)
Total harmonic distortion
Ambient temperature range
Storage temperature range
Features and Specifications
Pairs with most 60-cell/120 half-cell PV modules.
Dimensions not including mounting bracket
212 mm x 175 mm x 30.2 mm (approximate)
Environmental category / UV exposure rating
Torque specifications for fasteners
(Do not over torque)
• 6 mm (1/4”) mounting hardware: 5 N m (45 to 50 in-lbs.)
• 8 mm (5/16”) mounting hardware: 9 N m (80 to 85 in-
lbs.)
• When using UL 2703 mounting hardware, use the
manufacturer’s recommended torque value
Natural convection - no fans
Approved for wet locations
Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
.