5 How the Ditec HA7 works
12
Issue 2020-08-31
1021444-2.0
5.2.6
Closing
When the hold open time has elapsed, the operator will close the door automatically, using spring
force and motor. The door will slow to low speed at latch check before it reaches the fully closed
position. The door is kept closed by spring power or combined with extended closing torque by
the motor.
5.2.7
Wireless controlling
The door can be controlled by the app on a smartphone or a tablet.
5.2.8
Log
Events and errors can be displayed.
5.2.9
Extended closing torque
The motor will increase the closing torque when the door is closed or during closing. If the para-
meter is set to "0", the door will close with normal spring power.
5.2.10
Power assist
The motor will give/increase power assist when the door is opened manually. If the parameter is
set to "Off", the door will give no power assist.
5.2.11
Push and go
When the door is manually pushed it will perform an open / close cycle. Push and go is not active
in mode "Off/Closed".
5.2.12
Function of locks
The control unit has an available output of DC for external locks
The lock output is short circuit proof and can supply a lock with 12 V DC, max. 1200 mA or 24
V DC, max. 600 mA. Lock function is active in mode "Off / Closed" and "Exit Only".
Select 12 V DC or 24 V DC, locked with or without power
Lock release and opening delay
Lock kick to overcome binding in the locking device during closing
5.2.13
Impulses
Input for INNER / OUTER / KEY impulse.
5.2.14
Statistics
Record data of the action for the door.
5.2.15
Factory reset
Will restore all settings with factory default settings.