12 Start-up
12.2.9 Configuration parameters
Parameter name Default settings Value
Hold open time
5s
2s- 6h
Opening time
4.5s
4.5s - 9s
Closing time
4.5s
4.5s - 9s
Arm system
Push
Push / Pull
Push and go
Not active
Not active / Active
Power assist
Off Off / Low / Medium / High
Extend closing torque
0 (Lowest)
0 (Lowest) - 10 (Highest)
Stop on stall
Active
Not active / Active
Select lock voltage
12V
12V / 24V
Select lock power
Lock with power
Lock with power / Lock without power
Push and close
Not active
Not active / Active
Key impulse hold open time
5s
2s - 25s
Number of lock retries
1 time
0 - 2 times
Lock kick
Not active
Not active / Active
Reverse upon obstruction
Active
Not active / Active
Lock release time
0.5s
0s- 5s
Ratchet function
Not active
Not active / Active